Effects of temperature and flow regulated carbon dioxide cooling in longitudinally modulated cryogenic systems for comprehensive two-dimensional gas chromatography

被引:22
作者
Haglund, P [1 ]
Harju, M
Danielsson, C
Marriott, P
机构
[1] Umea Univ, Dept Chem, SE-90187 Umea, Sweden
[2] RMIT Univ, Dept Appl Chem, Melbourne, Vic 3001, Australia
关键词
gas chromatography; comprehensive two-dimensional; cryogenic systems; liquid crystals; peak shape; polychlorinated biphenyls;
D O I
10.1016/S0021-9673(02)00433-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Two different modes of temperature regulation in longitudinally modulated cryogenic systems (LMCSs) for comprehensive two-dimensional gas chromatography (GCXGC) were compared. Carbon dioxide was used as coolant. In the first mode of operation, the temperature of the trap was regulated to a pre-set temperature using a digital temperature controller ("the constant temperature mode"). In the second, the temperature was regulated to a fixed negative offset to the oven temperature by using a constant flow of CO, ("the constant flow mode"). A number of problems were occasionally observed using the constant temperature mode: (1) severe band broadening of high boiling analytes in the second dimension; (2) non-Gaussian reconstructed first-dimension peak profiles; (3) high background due to modulation of first-dimension column bleed. It was concluded that these problems were associated with inefficient solute remobilization at low LMCS trap temperatures (I and 2) or large trap temperature fluctuations (3). These problems could be avoided or significantly reduced by using the constant flow mode. Best results were obtained as the trap temperature was kept about 70 degreesC below the oven temperature. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:127 / 134
页数:8
相关论文
共 8 条
[1]   Simple, non-moving modulation interface for comprehensive two-dimensional gas chromatography [J].
Beens, J ;
Adahchour, M ;
Vreuls, RJJ ;
van Altena, K ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 2001, 919 (01) :127-132
[2]  
Kinghorn RM, 2000, HRC-J HIGH RES CHROM, V23, P245
[3]  
Kinghorn RM, 1998, J MICROCOLUMN SEP, V10, P611, DOI 10.1002/(SICI)1520-667X(1998)10:7<611::AID-MCS8>3.0.CO
[4]  
2-J
[5]  
Ledford EB, 2000, HRC-J HIGH RES CHROM, V23, P202
[6]  
Marriott PJ, 2000, HRC-J HIGH RES CHROM, V23, P253
[7]   Longitudinally modulated cryogenic system. A generally applicable approach to solute trapping and mobilization in gas chromatography [J].
Marriott, PJ ;
Kinghorn, RM .
ANALYTICAL CHEMISTRY, 1997, 69 (13) :2582-2588
[8]  
Phillips JB, 1999, HRC-J HIGH RES CHROM, V22, P3