Changes in transfer factor of the lung in response to bronchodilatation

被引:5
作者
Åkesson, U
Dahlström, JA
Wollmer, P [1 ]
机构
[1] Malmo Univ Hosp, Dept Clin Physiol, SE-20502 Malmo, Sweden
[2] Cty Hosp Helsingborg, Dept Clin Physiol, Helsingborg, Sweden
来源
CLINICAL PHYSIOLOGY | 2000年 / 20卷 / 01期
关键词
asthma; obstructive lung diseases; pulmonary diffusing capacity; respiratory function tests; terbutaline;
D O I
10.1046/j.1365-2281.2000.00213.x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Measurement of the transfer factor for carbon monoxide (T-LCO) is a widely used clinical lung function test. Although it is frequently applied in patients with bronchial obstruction, there is little information on the effects of bronchodilatation on the test. We therefore measured T-LCO in 40 patients before and after inhalation of terbutaline. T-LCO was measured with the single-breath technique in 20 patients and with the intra-breath technique in 20 patients. T-LCO was also measured in 20 healthy subjects with the single-breath technique. Forced expiratory volume (FEV1) increased from 2.9 +/- 1.1 to 3.2 +/- 1.2 l in patients with bronchial obstruction in response to terbutaline inhalation. T-LCO increased from 8.2 +/- 2.6 to 8.6 +/- 2.7 mmol min(-1) kPa(-1) (P< 0.001) and alveolar volume (V-A) from 5.74 +/- 1.21 to 5.90 +/- 1.21 l (P<0.001). There was no difference between the single-breath and the intra-breath techniques. There was little change in FEV1 in the healthy subjects in response to terbutaline. T-LCO increased from 10.2 +/- 2.1 to 10.5 +/- 2.2 mmol min(-1) kPa(-1) (P< 0.01), but there was no change in V-A. The increase in T-LCO in patients map partly be explained by improved distribution of the inhaled gas. In healthy subjects, terbutaline may increase pulmonary capillary volume. We conclude that bronchodilatation results in a small increase in T-LCO in patients with light to moderate bronchoconstriction as well as in healthy subjects. The effect is small and should in most cases be simple to account for in the interpretation of pulmonary tests, provided the patient's treatment is known.
引用
收藏
页码:14 / 18
页数:5
相关论文
共 13 条
[1]  
BERGLUND E, 1963, ACTA MED SCAND, V173, P185
[2]  
CHINN DJ, 1988, EUR RESPIR J, V1, P15
[3]   SINGLE-BREATH DIFFUSING-CAPACITY FOR CARBON-MONOXIDE IN STABLE ASTHMA [J].
COLLARD, P ;
NJINOU, B ;
NEJADNIK, B ;
KEYEUX, A ;
FRANS, A .
CHEST, 1994, 105 (05) :1426-1429
[4]   STANDARDIZATION OF THE MEASUREMENT OF TRANSFER-FACTOR (DIFFUSING-CAPACITY) - REPORT WORKING PARTY STANDARDIZATION OF LUNG-FUNCTION TESTS EUROPEAN-COMMUNITY FOR STEEL AND COAL - OFFICIAL STATEMENT OF THE EUROPEAN RESPIRATORY SOCIETY [J].
COTES, JE ;
CHINN, DJ ;
QUANJER, PH ;
ROCA, J ;
YERNAULT, JC .
EUROPEAN RESPIRATORY JOURNAL, 1993, 6 :41-52
[5]   PULMONARY VASODILATATION AND AUGMENTATION OF RIGHT VENTRICULAR-FUNCTION FOLLOWING TERBUTALINE INFUSION IN SEVERE CHRONIC PULMONARY-DISEASE [J].
ELIASEN, K ;
RINGSTED, C ;
MUNCK, O ;
HJORTSO, E ;
HESLET, L .
CLINICAL PHYSIOLOGY, 1991, 11 (03) :231-243
[6]  
GRAHAM BL, 1984, AM REV RESPIR DIS, V129, P403
[7]   NORMAL VALUES FOR SINGLE EXHALATION DIFFUSING-CAPACITY AND PULMONARY CAPILLARY BLOOD-FLOW IN SITTING, SUPINE POSITIONS, AND DURING MILD EXERCISE [J].
HUANG, YCT ;
HELMS, MJ ;
MACINTYRE, NR .
CHEST, 1994, 105 (02) :501-508
[8]   EVALUATION OF THE SINGLE-BREATH DIFFUSING-CAPACITY IN ASTHMA AND CYSTIC-FIBROSIS [J].
KEENS, TG ;
MANSELL, A ;
KRASTINS, IRB ;
LEVISON, H ;
BRYAN, AC ;
HYLAND, RH ;
ZAMEL, N .
CHEST, 1979, 76 (01) :41-44
[9]   SINGLE BREATH CARBON-MONOXIDE TRANSFER-FACTOR IN DIFFERENT FORMS OF CHRONIC AIR-FLOW OBSTRUCTION IN A GENERAL-POPULATION SAMPLE [J].
KNUDSON, RJ ;
KALTENBORN, WT ;
BURROWS, B .
THORAX, 1990, 45 (07) :514-519
[10]   PULMONARY DIFFUSING-CAPACITY MEASURED AT MULTIPLE INTERVALS DURING A SINGLE EXHALATION IN MAN [J].
NEWTH, CJL ;
COTTON, DJ ;
NADEL, JA .
JOURNAL OF APPLIED PHYSIOLOGY, 1977, 43 (04) :617-625