摘要
The relationship between the conformability of adhesive tape, the mechanical property of the adhesive tape not to interfere with skin movement, and irritation of the skin was investigated. In order to assess the conformability of adhesive tape to the skin, a uniaxial method employing film strips connected to a strain gauge was used to measure the elastic property of the skin, with or without application of various elastic tapes. The tension loaded on the strain gauge was measured while the skin was extended by 15% of its original length in a direction across the humeral axis on the flexor side of the upper right arm. The most elastic adhesive tape showed the best conformity to the skin. The same adhesive tapes were applied on the flexor side of both upper arms so that the tape held a piece of sanitary cotton in place for 24 h. Dermal irritation was not so remarkable in the skin under the inner part of the tapes. On the other hand, the skin reaction was much more severe on the skin under the edge portion of the applied tape which showed poor conformability to the skin. These findings seemed to indicate that the skin reaction was caused by localized distortion of the skin under the edge portion of the applied tapes, during movement of the underlying muscle. Actually, the distortion of the skin surface was great in the areas immediately outside the edge of the applied tape. In conclusion, adhesive tape conformable to skin movement reduced localized distortion of the skin during application, resulting in low irritation at the edge of the applied tape. (C) Munksgaard, 1997.
引用
收藏
页码:173 / 178
页数:6
相关论文
共 8 条
[1]  
Berardesca E., 1986, BIOENG SKIN, V2, P261
[2]   EXPERIMENTAL-METHOD FOR DETERMINING 2-DIMENSIONAL MECHANICAL-PROPERTIES OF LIVING HUMAN-SKIN [J].
COOK, T ;
ALEXANDER, H ;
COHEN, M .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1977, 15 (04) :381-390
[3]   MECHANICAL-PROPERTIES OF SKIN INVIVO - PORTABLE HAND-HELD EXTENSOMETER [J].
GUNNER, CW ;
HUTTON, WC ;
BURLIN, TE .
BRITISH JOURNAL OF DERMATOLOGY, 1979, 100 (02) :161-163
[4]   THE MEASUREMENT AND MODELING OF THE MECHANICAL-PROPERTIES OF HUMAN-SKIN INVIVO .1. THE MEASUREMENT [J].
MANSCHOT, JFM ;
BRAKKEE, AJM .
JOURNAL OF BIOMECHANICS, 1986, 19 (07) :511-515
[5]  
Ohura T, 1980, Ann Plast Surg, V5, P74, DOI 10.1097/00000637-198007000-00011
[6]  
Satas D, 1989, HDB PRESSURE SENSITI, P627
[7]   RECENT DEVELOPMENTS IN SURGICAL DRESSINGS [J].
SEYMOUR, DE .
JOURNAL OF PHARMACY AND PHARMACOLOGY, 1957, 9 (12) :802-813
[8]  
TACKER JG, 1977, REV SCI INSTRUM, V48, P181