Catheter visualisation in MR tomography: First animal experimental experiences with field inhomogeneity catheters.

被引:16
作者
Adam, G
Glowinski, A
Neuerburg, J
Bucker, A
vanVaals, JJ
Hurtak, W
Gunther, RW
机构
[1] CORDIS BV,RODEN,NETHERLANDS
[2] PHILIPS MED SYST,BEST,NETHERLANDS
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 1997年 / 166卷 / 04期
关键词
MRI; interventional MR; catheter visualisation;
D O I
10.1055/s-2007-1015433
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the feasibility of a new developed field inhomogeneity catheter for interventional MR imaging in vivo. Materials and methods: Three different prototypes of a field inhomogeneity catheter were investigated in 6 pigs. The catheters were introduced in Seldinger technique via the femoral vessels over a guide wire on an interventional MR system (Philips Gyroscan NT combined with a C-arm fluoroscopy unit [Philips BV 212]). Catheters were placed in veins and arteries. The catheter position was controlled by a fast gradient echo sequence (Turbo Field Echo[TFE]). Results: Catheters were introduced over a guide wire without complications in all cases. Using the field inhomogeneity concept, catheters were easily visualised in the inferior vena cava and the aorta by the fast gradient echo technique on MR in all cases. Although aortic branches were successfully cannulated, the catheters were not displayed by the TFE technique due to the complex and tortuous anatomy. All animals survived the experiments without complications. Conclusion: MR guided visualisation of a field inhomogeneity catheter is a simple concept: which can be realised on each MR scanner and may allow intravascular MR guided interventions in future.
引用
收藏
页码:324 / 328
页数:5
相关论文
共 7 条
[1]  
FRAHM C, 1996, ERGEBNISSE FORTSCHR, V164, P62
[2]   The technique of MRT aided abdominal drainage using an open low field magnet. [J].
Gehl, HB ;
Frahm, C ;
Schimmelpenning, H ;
Weiss, HD .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1996, 165 (01) :70-73
[3]  
GLOWINSKI A, 1996, ROFO FORTSCHR RONTG, V164, pS114
[4]   INTRAVASCULAR MR TRACKING CATHETER - PRELIMINARY EXPERIMENTAL EVALUATION [J].
LEUNG, DA ;
DEBATIN, JF ;
WILDERMUTH, S ;
MCKINNON, GC ;
HOLTZ, D ;
DUMOULIN, CL ;
DARROW, RD ;
HOFMANN, E ;
VONSCHULTHESS, GK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (05) :1265-1270
[5]   SUPERCONDUCTING OPEN-CONFIGURATION MR-IMAGING SYSTEM FOR IMAGE-GUIDED THERAPY [J].
SCHENCK, JF ;
JOLESZ, FA ;
ROEMER, PB ;
CLINE, HE ;
LORENSEN, WE ;
KIKINIS, R ;
SILVERMAN, SG ;
HARDY, CJ ;
BARBER, WD ;
LASKARIS, ET ;
DORRI, B ;
NEWMAN, RW ;
HOLLEY, CE ;
COLLICK, BD ;
DIETZ, DP ;
MACK, DC ;
AINSLIE, MD ;
JASKOLSKI, PL ;
FIGUEIRA, MR ;
LEHN, JCV ;
SOUZA, SP ;
DUMOULIN, CL ;
DARROW, RD ;
STPETERS, RL ;
ROHLING, KW ;
WATKINS, RD ;
EISNER, DR ;
BLUMENFELD, SM ;
VOSBURGH, KG .
RADIOLOGY, 1995, 195 (03) :805-814
[6]  
VANVAALS JJ, 1995, RADIOLOGY, V197, P220
[7]  
VOGL TJ, 1995, RADIOLOGE, V35, P188