Dynamic responses of biofilters to changes in the operating conditions in the process of removing toluene and xylene from air

被引:30
作者
Marek, J
Paca, J
Gerrard, AM
机构
[1] Univ Chem Technol, Dept Fermentat Chem & Bioengn, Prague 16628, Czech Republic
[2] Univ Teesside, Sch Sci & Technol, Middlesbrough TS1 3BA, Cleveland, England
来源
ACTA BIOTECHNOLOGICA | 2000年 / 20卷 / 01期
关键词
D O I
10.1002/abio.370200104
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The dynamic behaviour of biofilters intended to remove toluene and xylene from air was studied during transient states. Laboratory scale biofilters were filled with a mixture of peat, bark and wood and inoculated with a mixed microbial population. Toluene and xylene were applied both as single pollutants and as mixtures. Attention was focused on the evaluation of the following transients: the response of biofilters to step changes and peaks in pollutant concentrations, the effect of changes between single and multiple pollutant loadings and the response to shutdown periods. The biofilters demonstrated a good dynamic stability during transient states induced by changes in inlet pollutant concentrations. Their time periods did not exceed three hours. No interaction between xylene and toluene degradation was observed during changes in loading with single pollutants or their mixture. The performance interruptions lasting less than 24 hours were found to have no significant influence on the removal efficiency of biofilters. When the biofilters were reacclimated after longer starvation periods, a short temporary decrease in efficiency whose minimum and duration were proportional to the length of a preceding shutdown period was observed. The longest starvation period (7 days) resulted in a reacclimation lasting 7 hours only. Adaptations of a microbial population to new operating conditions as well as sorption/desorption processes were suggested as the main factors influencing the dynamic response characteristics.
引用
收藏
页码:17 / 29
页数:13
相关论文
共 19 条
[1]   Practical experience with an industrial biofilter treating solvent vapour loads of varying magnitude and composition [J].
Campbell, HJ ;
Connor, MA .
PURE AND APPLIED CHEMISTRY, 1997, 69 (11) :2411-2424
[2]   Transient behavior of biofilters: Start-up, carbon balances, and interactions between pollutants [J].
Deshusses, MA .
JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 1997, 123 (06) :563-568
[3]  
Deshusses MA, 1996, BIOTECHNOL BIOENG, V49, P587, DOI 10.1002/(SICI)1097-0290(19960305)49:5&lt
[4]  
587::AID-BIT12&gt
[5]  
3.0.CO
[6]  
2-7
[7]  
DESHUSSES MA, 1995, ENVIRON SCI TECHNOL, V29, P1059, DOI 10.1021/es00004a028
[8]   BEHAVIOR OF BIOFILTERS FOR WASTE AIR BIOTREATMENT .1. DYNAMIC-MODEL DEVELOPMENT [J].
DESHUSSES, MA ;
HAMER, G ;
DUNN, IJ .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1995, 29 (04) :1048-1058
[9]  
Gerrard AM, 1997, INST CHEM E, P131
[10]  
Gerrard AM, 1997, 1997 JUBILEE RESEARCH EVENT, VOLS 1 AND 2, P117