Analysis of proposed three-class classification decision rules in terms of the ideal observer decision

被引:12
作者
Edwards, Darrin C. [1 ]
Metz, Charles E. [1 ]
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
关键词
ROC analysis; three-class classification; ideal observer decision rules;
D O I
10.1016/j.jmp.2006.05.004
中图分类号
O1 [数学];
学科分类号
0701 ; 070101 ;
摘要
We analyze recently proposed decision rules for three-class classification from the point of view of ideal observer decision theory. We consider three-class decision rules proposed by Scurfield, by Chan et al., and by Mossman. Scurfield's decision rule is shown to be a special case of the three-class ideal observer decision rule in three different situations. Chan et al. start with an ideal observer model and specify its decision-consequence utility structure in a way that causes two of the decision lines used by the ideal observer to overlap and the third line to become undefined. Finally, we show that, for a particular and obvious choice of ideal-observer-related decision variables, the Mossman decision rule cannot be a special case of the ideal observer decision rule. Despite the considerable difficulties presented by the three-class classification task, the three-class ideal observer provides a useful framework for analyzing a variety of three-class decision strategies. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:478 / 487
页数:10
相关论文
共 31 条
[1]  
[Anonymous], [No title captured]
[2]   AUTOMATED SEGMENTATION OF DIGITIZED MAMMOGRAMS [J].
BICK, U ;
GIGER, ML ;
SCHMIDT, RA ;
NISHIKAWA, RM ;
WOLVERTON, DE ;
DOI, K .
ACADEMIC RADIOLOGY, 1995, 2 (01) :1-9
[3]  
BUNCH PC, 1978, J APPL PHOTOGR ENG, V4, P166
[4]   Statistical power in observer-performance studies: Comparison of the receiver operating characteristic and free-response methods in tasks involving localization [J].
Chakraborty, D .
ACADEMIC RADIOLOGY, 2002, 9 (02) :147-156
[5]   MAXIMUM-LIKELIHOOD ANALYSIS OF FREE-RESPONSE RECEIVER OPERATING CHARACTERISTIC (FROC) DATA [J].
CHAKRABORTY, DP .
MEDICAL PHYSICS, 1989, 16 (04) :561-568
[6]   Design of three-class classifiers in computer-aided diagnosis: Monte Carlo simulation study [J].
Chan, HP ;
Sahiner, B ;
Hadjiiski, LM ;
Petrick, N ;
Zhou, C .
MEDICAL IMAGING 2003: IMAGE PROCESSING, PTS 1-3, 2003, 5032 :567-578
[7]   Comparing three-class diagnostic tests by three-way ROC analysis [J].
Dreiseitl, S ;
Ohno-Machado, L ;
Binder, M .
MEDICAL DECISION MAKING, 2000, 20 (03) :323-331
[8]   The hypervolume under the ROC hypersurface of "near-guessing" and "near-perfect" observers in N-class classification tasks [J].
Edwards, DC ;
Metz, CE ;
Nishikawa, RM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (03) :293-299
[9]   Ideal observers and optimal ROC hypersurfaces in N-class classification [J].
Edwards, DC ;
Metz, CE ;
Kupinski, MA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (07) :891-895
[10]   Estimating three-class ideal observer decision variables for computerized detection and classification of mammographic mass lesions [J].
Edwards, DC ;
Lan, L ;
Metz, CE ;
Giger, ML ;
Nishikawa, RM .
MEDICAL PHYSICS, 2004, 31 (01) :81-90