Stability analysis of power systems described with detailed models by automatic method

被引:5
作者
Colvara, L. D. [1 ]
机构
[1] Sao Paulo State Univ, UNESP, Elect Engn Dept IIha Solteira, Sao Paulo, Brazil
关键词
Power system transient stability; Control devices; Energy function; Automatic method;
D O I
10.1016/j.ijepes.2008.10.002
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
080906 [电磁信息功能材料与结构]; 082806 [农业信息与电气工程];
摘要
The power system stability analysis is approached taking into explicit account the dynamic performance of generators internal voltages and control devices. The proposed method is not a direct method in the usual sense since conclusion for stability or instability is not exclusively based on energy function considerations but it is automatic since the conclusion is achieved without an analyst intervention. The stability test accounts for the nonconservative nature of the system with control devices such as the automatic voltage regulator (AVR) and automatic generation control (AGC) in contrast with the well-known direct methods. An energy function is derived for the system with machines forth-order model, AVR and AGC and it is used to start the analysis procedure and to point out criticalities. The conclusive analysis itself is made by means of a method based on the definition of a region surrounding the equilibrium point where the system net torque is equilibrium restorative. This region is named positive synchronization region (PSR). Since the definition of the PSR boundaries have no dependence on modelling approximation, the PSR test conduces to reliable results. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:139 / 145
页数:7
相关论文
共 10 条
[1]
Identification of the vulnerable transmission segment and cluster of critical machines using line transient potential energy [J].
Cai, G. W. ;
Chan, K. W. ;
Yuan, W. P. ;
Mu, G. .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2007, 29 (03) :199-207
[2]
DIRECT STABILITY ANALYSIS OF ELECTRIC-POWER SYSTEMS USING ENERGY FUNCTIONS - THEORY, APPLICATIONS, AND PERSPECTIVE [J].
CHIANG, HD ;
CHU, CC ;
CAULEY, G .
PROCEEDINGS OF THE IEEE, 1995, 83 (11) :1497-1529
[3]
Stability analysis of power system including facts (TCSC) effects by direct method approach [J].
Colvara, LD ;
Araujo, SCB ;
Festraits, EB .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2005, 27 (04) :264-274
[4]
FAD-ATC: A new method for computing dynamic ATC [J].
Eidiani, M ;
Shanechi, MHM .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2006, 28 (02) :109-118
[5]
HSU L, 1987, WORLD C AUT CONTR IF, V10
[6]
Kundur P., 1994, TRANSIENT STABILITY, P827
[7]
Pai M. A., 1981, POWER SYSTEM STABILI, DOI 10.1109/proc.1984.13099
[8]
SILVA FHJ, 2003, IEEE, V3, P1732
[9]
Vidyasagar M., 1978, Nonlinear systems analysis
[10]
ZOU Y, 2003, IEEE T CIRC SYST 1, V50