Comparison of surface plasmon resonance and capacitive immunosensors for cancer antigen 125 detection in human serum samples

被引:83
作者
Suwansa-ard, Siriwan [2 ,3 ]
Kanatharana, Proespichaya [2 ,3 ]
Asawatreratanakul, Punnee [4 ]
Wongkittisuksa, Booncharoen [5 ]
Limsakul, Chusak [5 ]
Thavarungkul, Panote [1 ,2 ]
机构
[1] Prince Songkla Univ, Fac Sci, Dept Phys, Trace Anal & Biosensor Res Ctr, Hat Yai 90112, Songkhla, Thailand
[2] Prince Songkla Univ, Fac Sci, Ctr Innovat Chem, Hat Yai 90112, Songkhla, Thailand
[3] Prince Songkla Univ, Fac Sci, Dept Chem, Hat Yai 90112, Songkhla, Thailand
[4] Prince Songkla Univ, Fac Sci, Dept Biochem, Hat Yai 90112, Songkhla, Thailand
[5] Prince Songkla Univ, Fac Engn, Dept Elect Engn, Hat Yai 90112, Songkhla, Thailand
关键词
Surface plasmon resonance; Capacitance; Label-free immunosensor; Cancer antigen 125; GOLD NANOPARTICLES; CARCINOMA ANTIGEN-125; OVARIAN-CANCER; TUMOR-MARKERS; ANTIBODY; IMMUNOASSAY; THIOUREA; ELECTRODE; BINDING; CA-125;
D O I
10.1016/j.bios.2009.04.008
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This paper presents a comparison between surface plasmon resonance (SPR) and capacitive immunosensors for a flow injection label-free detection of cancer antigen 125 (CA 125) in human serum. Anti-CA 125 was immobilized on gold surface through a self-assembled monolayer. Parameters affecting the responses of each system were optimized. Under optimal conditions, SPR provided a detection limit of 0.1 U ml(-1) while 0.05 U ml(-1) was obtained for the capacitive system. Linearity for SPR was between 0.1 and 40 U ml(-1) and 0.05-40 U ml(-1) for capacitive system. These immunosensors were applied to analyze CA 125 concentrations in human serum samples and compared with conventional enzyme linked fluorescent assay (ELFA). Both systems showed good agreement with ELFA (P < 0.05). Moreover, these immunosensors were very stable and provided good reproducible responses after regeneration, up to 32 times for SPR and 48 times for capacitive system with relative standard deviation lower than 4%. The SPR immunosensor provided advantages in term of fast response and real-time monitoring while capacitive immunosensor offered a sensitive and cost-effective method for CA 125 detection. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:3436 / 3441
页数:6
相关论文
共 41 条
[1]  
Andersson K, 1999, J MOL RECOGNIT, V12, P310, DOI 10.1002/(SICI)1099-1352(199909/10)12:5<310::AID-JMR470>3.0.CO
[2]  
2-5
[3]  
[Anonymous], 2006, R LANG ENV STAT COMP
[4]  
[Anonymous], [No title captured]
[5]   Microfluidic immunosensor systems [J].
Bange, A ;
Halsall, HB ;
Heineman, WR .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (12) :2488-2503
[6]   An immunological interleukin-6 capacitive biosensor using perturbation with a potentiostatic step [J].
Berggren, C ;
Bjarnason, B ;
Johansson, G .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (10) :1061-1068
[7]   Capacitance measurements of antibody-antigen interactions in a flow system [J].
Berggren, C ;
Johansson, G .
ANALYTICAL CHEMISTRY, 1997, 69 (18) :3651-3657
[8]  
*BIOM, 2004, VIDAS CA 125 2
[9]   RECOMMENDATIONS FOR NOMENCLATURE OF ION-SELECTIVE ELECTRODES - (IUPAC RECOMMENDATIONS 1994) [J].
BUCK, RP ;
LINDNER, E .
PURE AND APPLIED CHEMISTRY, 1994, 66 (12) :2527-2536
[10]   Real-Time, label-free monitorine, of tumor antigen and serum antibody interactions [J].
Campagnolo, C ;
Meyers, KJ ;
Ryan, T ;
Atkinson, RC ;
Chen, YT ;
Scanlan, MJ ;
Ritter, G ;
Old, LJ ;
Batt, CA .
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2004, 61 (03) :283-298