Comparison of two carbon analysis methods for monitoring diesel particulate levels in mines

被引:11
作者
Birch, ME
Dahmann, D
Fricke, HH
机构
[1] NIOSH, US Dept HHS, Publ Hlth Serv, Ctr Dis Control & Prevent,Div Phys Sci & Engn, Cincinnati, OH 45226 USA
[2] Bergbau Berufsgenossenschaft, Inst Gefahrstoff Forsch, D-44789 Bochum, Germany
来源
JOURNAL OF ENVIRONMENTAL MONITORING | 1999年 / 1卷 / 06期
关键词
D O I
10.1039/a905204f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two carbon analysis methods are currently being applied to the occupational monitoring of diesel particulate matter. Both methods are based on thermal techniques for the determination of organic and elemental carbon. In Germany, method ZH 1/120.44 has been published. This method, or a variation of it, is being used for compliance measurements in several European countries, and a Comite Europeen de Normalization Working Group was formed recently to address the establishment of a European measurement standard. In the USA, a 'thermal-optical' method has been published as Method 5040 by the National Institute for Occupational Safety and Health. As with ZH 1/120.44, organic and elemental carbon are determined through temperature and atmosphere' control, but different instrumentation and analysis conditions are used. Although the two methods are similar in principle, they gave statistically different results in a previous interlaboratory comparison. Because different instruments and operating conditions are used, between-method differences can be expected in some cases. Reasonable agreement is expected when the sample contains no other tie., non-diesel) sources of carbonaceous particulate and the organic fraction is essentially removed below about 500 degrees C. Airborne particulate samples from some mines may meet these criteria. Comparison data on samples from mines are important because the methods are being applied in this workplace for occupational monitoring and epidemiological studies. In this paper, results of a recent comparison on samples collected in a Canadian mine are reported. As seen in a previous comparison, there was good agreement between the total carbon results found by the two methods, with ZH 1/120.44 giving about 6% less carbon than Method 5040. Differences in the organic and elemental carbon results were again seen, but they were much smaller than those obtained in the previous comparison. The relatively small differences in the split between organic and elemental carbon are attributed to the different thermal programs used.
引用
收藏
页码:541 / 544
页数:4
相关论文
共 9 条
[1]  
BAUER HD, 1991, STAUB REINHALT LUFT, V51, P319
[2]  
BAUER HD, 1990, KOMPASS, V100, P516
[3]  
Birch ME, 1998, ANALYST, V123, P851
[4]   Elemental carbon-based method for monitoring occupational exposures to particulate diesel exhaust [J].
Birch, ME ;
Cary, RA .
AEROSOL SCIENCE AND TECHNOLOGY, 1996, 25 (03) :221-241
[5]  
BIRCH ME, 1998, DHHS NIOSH PUBLICATI
[6]   International round robin tests on the measurement of carbon in diesel exhaust particulates [J].
Guillemin, M ;
Cachier, H ;
Chini, C ;
Dabill, D ;
Dahmann, D ;
Diebold, F ;
Fischer, A ;
Fricke, HH ;
Groves, JA ;
Hebisch, R ;
Houpillart, M ;
Israel, G ;
Mattenklott, M ;
Moldenhauer, W ;
Sandino, JP ;
Schlums, C ;
Sutter, E ;
Tucek, E .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 1997, 70 (03) :161-172
[7]  
IARC monographs on the evaluation of carcinogenic risks to humans, 1989, IARC MON EV CARC RIS, V46
[8]  
National Institute for Occupational Safety and Health (NIOSH), 1988, DHHS NIOSH PUBL
[9]  
*ZH, 1995, 112044 ZH