Comparison of sweat loss estimates for women during prolonged high-intensity running

被引:43
作者
Cheuvront, SN
Haymes, EM
Sawka, MN
机构
[1] Florida State Univ, Dept Nutr Food & Exercise Sci, Tallahassee, FL 32306 USA
[2] USA, Environm Med Res Inst, Thermal & Mt Med Div, Natick, MA 01760 USA
关键词
hydration; endurance exercise; fluid balance; gender; fluid requirements;
D O I
10.1097/00005768-200208000-00017
中图分类号
G8 [体育];
学科分类号
04 [教育学]; 0403 [体育学];
摘要
Purpose: This study evaluated the error produced by four commonly used field estimates and two prediction equations of total body sweat loss. Methods: Eight women distance runners were studied during a 30-km treadmill run (similar to70% <(V)over dot>O-2max) in a warm (30degreesC T-db) and a cool (14degreesC T-db) environment. Total sweat loss (TSL) was determined from changes in body mass corrected for fluid intake (FI), urine losses (UL), clothing (trapped sweat, TS), CO2-O-2 exchange (metabolic mass loss, MML), and respiratory water loss (RWL). TSL was compared with four estimates of sweat losses (often employed in the field) from body mass changes corrected for: a) FI only (F-1); b) FI and TS (F-2): c) FI and UL (F-3); or d) FI, TS, and UL (F-4). Two prediction equations were used also for comparison to TSL values. Results: In the warm environment, F-1, F-3, and F-4 accurately estimated (0.2-6.9%; P > 0.05) TSL, whereas F-2 produced a large error (15.3%; P < 0.05). In the cool environment, all four estimates produced large errors (14-41%; P < 0.05). Both prediction equations markedly underestimated (20-22%) TSL in the warm environment and underestimated (41%) or overestimated (20%) TSL in the cool environment. Conclusion: TSL can be accurately estimated from changes in body mass using F-1, F-3, or F-4 methods in hot environments; however, none of the methods accurately estimated actual TSL values in a cool environment. Neither prediction equation provided accurate estimates of TSL in warm or cool conditions for women runners. These results illustrate the difficulty of accurately estimating and predicting sweat losses in the field.
引用
收藏
页码:1344 / 1350
页数:7
相关论文
共 17 条
[1]
BARR SI, 1989, J AM DIET ASSOC, V89, P1629
[2]
Thermoregulation and marathon running biological and environmental influences [J].
Cheuvront, SN ;
Haymes, EM .
SPORTS MEDICINE, 2001, 31 (10) :743-762
[3]
CONSOLAZIO FC, 1963, PHYSL MEASUREMENTS M, P313
[4]
American College of Sports Medicine position stand - Exercise and fluid replacement [J].
Convertino, VA ;
Armstrong, LE ;
Coyle, EF ;
Mack, GW ;
Sawka, MN ;
Senay, LC ;
Sherman, WM .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1996, 28 (01) :R1-R7
[5]
Costill DL, 1969, Medicine and Science in Sports and Exercise, V1, P81, DOI DOI 10.1249/00005768-196906000-00005
[6]
Gagge A.P., 2011, HDB PHYSIOL SECT 4, DOI 10.1002/cphy.cp040104
[7]
Haymes E.M., 1984, Physician SportsMed, V12, P45, DOI DOI 10.1080/00913847.1984.11701794
[8]
HAYMES EM, 1986, ENV HUMAN PERFORMANC, P43
[9]
A 1% treadmill grade most accurately reflects the energetic cost of outdoor running [J].
Jones, AM ;
Doust, JH .
JOURNAL OF SPORTS SCIENCES, 1996, 14 (04) :321-327
[10]
FLUID REPLACEMENT DURING EXERCISE IN THE HEAT - REVIEW AND RECOMMENDATIONS [J].
MILLARDSTAFFORD, M .
SPORTS MEDICINE, 1992, 13 (04) :223-233