A chemodosimeter approach to fluorescent sensing and imaging of inorganic and methylmercury species

被引:169
作者
Santra, Mithun [1 ,2 ]
Ryu, Dowook [1 ,2 ]
Chatterjee, Amrita [1 ,2 ]
Ko, Sung-Kyun [3 ]
Shin, Injae [3 ]
Ahn, Kyo Han [1 ,2 ]
机构
[1] POSTECH, Ctr Electrophoto Behav Adv Mol Syst, Pohang 790784, South Korea
[2] POSTECH, Dept Chem, Pohang 790784, South Korea
[3] Yonsei Univ, Dept Chem, Seoul 120749, South Korea
关键词
MERCURIC ION; HG2+; CHEMOSENSOR; DESIGN; HG(II); SENSOR; PROBE; WATER;
D O I
10.1039/b900380k
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A highly sensitive fluorescent turn-on probe specific for methylmercury species as well as inorganic mercury ions has been developed on the basis of mercury ion-promoted hydrolysis of a fluorescein-derived aryl vinyl ether.
引用
收藏
页码:2115 / 2117
页数:3
相关论文
共 25 条
[1]  
[Anonymous], 1999, AGENCY TOXIC SUBSTAN
[2]  
*ATSDR, 2005, TOXPO MERC
[3]   METHYLMERCURY POISONING IN IRAQ - INTERUNIVERSITY REPORT [J].
BAKIR, F ;
DAMLUJI, SF ;
AMINZAKI, L ;
MURTADHA, M ;
KHALIDI, A ;
ALRAWI, NY ;
TIKRITI, S ;
DHAHIR, HI ;
CLARKSON, TW ;
SMITH, JC ;
DOHERTY, RA .
SCIENCE, 1973, 181 (4096) :230-241
[4]   Highly selective chromogenic and redox or fluorescent sensors of Hg2+ in aqueous environment based on 1,4-disubstituted azines [J].
Caballero, A ;
Martínez, R ;
Lloveras, V ;
Ratera, I ;
Vidal-Gancedo, J ;
Wurst, K ;
Tárraga, A ;
Molina, P ;
Veciana, J .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2005, 127 (45) :15666-15667
[5]   The toxicology of mercury and its chemical compounds [J].
Clarkson, Thomas W. ;
Magos, Laszlo .
CRITICAL REVIEWS IN TOXICOLOGY, 2006, 36 (08) :609-662
[6]   An organopalladium chromogenic chemodosimeter for the selective naked-eye detection of Hg2+ and MeHg+ in water-ethanol 1:1 mixture [J].
del Campo, O. ;
Carbayo, A. ;
Cuevas, J. V. ;
Munoz, A. ;
Garcia-Herbosa, G. ;
Moreno, D. ;
Ballesteros, E. ;
Basurto, S. ;
Gomez, T. ;
Torroba, T. .
CHEMICAL COMMUNICATIONS, 2008, (38) :4576-4578
[7]   Coupling selectivity with sensitivity in an integrated chemosensor framework:: Design of a Hg2+-responsive probe, operating above 500 nm [J].
Descalzo, AB ;
Martínez-Máñez, R ;
Radeglia, R ;
Rurack, K ;
Soto, J .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2003, 125 (12) :3418-3419
[8]   A highly selective and sensitive fluorescent chemosensor for Hg2+ in neutral buffer aqueous solution [J].
Guo, XF ;
Qian, XH ;
Jia, LH .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2004, 126 (08) :2272-2273
[9]   Toxicity, sources and biogeochemical cycle of mercury [J].
Jitaru, P ;
Adams, F .
JOURNAL DE PHYSIQUE IV, 2004, 121 :185-193
[10]   In vivo monitoring of mercury ions using a rhodamine-based molecular probe [J].
Ko, Sung-Kyun ;
Yang, Young-Keun ;
Tae, Jinsung ;
Shin, Injae .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (43) :14150-14155