PMU configuration for system dynamic performance measurement in large multiarea power systems

被引:75
作者
Kamwa, I [1 ]
Grondin, R [1 ]
机构
[1] Inst Rech Hydro Quebec, IREQ, Power Syst Anal Operat & Control Dept, Varennes, PQ J3X 1S1, Canada
关键词
digital fault recorders; optimal sensor location; phasor measurement unit (PMU); state estimation; wide-area control; wide-area monitoring;
D O I
10.1109/TPWRS.2002.1007908
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Effective assessment of the dynamic performance of the power system requires wide-area information from properly distributed phasor measurement units (PMUs). However, to maximize the information content of the captured signals, the sensors need to be located appropriately, with due account given to the structural properties underlying the given system. In this paper, two numerical algorithms are proposed to achieve this goal. They aim to maximize the overall sensor response while minimizing-the correlation among sensor outputs so as to minimize the redundant information provided by multiple sensors. The sensor responses of interest are the bus voltage magnitude, and the angle and frequency coherency indexes, which are estimated by means of a statistical sampling of power system response signals from a transient-stability program. Through the "successive addition" scheme, one of these algorithms easily incorporates mandatory locations such as tie-line busses and large generator step-up transformers. The proposed approaches are first illustrated on the Hydro-Quebec transmission grid and then on a 9-area/67-bus/23-machine test network designed with well-defined geographical boundaries and pre-specified weak interties between electrically coherent areas.
引用
收藏
页码:385 / 394
页数:10
相关论文
共 27 条
[1]   POWER-SYSTEM OBSERVABILITY WITH MINIMAL PHASOR MEASUREMENT PLACEMENT [J].
BALDWIN, TL ;
MILI, L ;
BOISEN, MB ;
ADAPA, R .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1993, 8 (02) :707-715
[2]   VOLTAGE STABILITY ASSESSMENT THROUGH MEASUREMENT OF A REDUCED STATE-VECTOR [J].
BEGOVIC, MM ;
PHADKE, AG .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1990, 5 (01) :198-203
[3]  
BURNETT RO, 1994, IEEE COMPUT APPL POW, V7
[4]  
*CIGRE, 1998, 34106 CIGRE
[5]  
CONEJO A, 1993, EUR T ELEC ENG, V5, P359
[6]   Time-varying contingency screening for dynamic security assessment using intelligent-systems techniques [J].
Kamwa, I ;
Grondin, R ;
Loud, L .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2001, 16 (03) :526-536
[7]   Wide-area measurement based stabilizing control of large power systems -: A decentralized/hierarchical approach [J].
Kamwa, I ;
Grondin, R ;
Hébert, Y .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2001, 16 (01) :136-153
[8]   A TOOL FOR THE EVALUATION AND SELECTION OF STATE ESTIMATOR MEASUREMENT SCHEMES [J].
KORRES, GN ;
CONTAXIS, GC .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1994, 9 (02) :1110-1116
[9]  
LAGNOTTE P, 1989, IEEE T POWER SYST, V4, P479
[10]  
LAWLER JS, 1982, IEEE T POWER AP SYST, V101, P1070, DOI 10.1109/TPAS.1982.317413