Effect of experience on quality of canal preparation with rotary nickel-titanium files

被引:61
作者
Baumann, MA [1 ]
Roth, A [1 ]
机构
[1] Univ Cologne, Sch Dent, Dept Operat Dent & Periodontol, D-50931 Cologne, Germany
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS | 1999年 / 88卷 / 06期
关键词
D O I
10.1016/S1079-2104(99)70015-6
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. The purpose of this study was to compare inexperienced third-year dental students and experienced dentists with respect to their ability to use rotary nickel-titanium files, specifically with respect to root canal shape and instrument fracture. Study design. A total of 102 simulated endodontic plastic blocks were used. Twelve untrained dental students and 12 practitioners prepared 3 blocks each, and an endodontist and a trained student completed 15 blocks each. Blocks were filmed before instrumentation and then prepared to ISO 35; they were filmed again after canal preparation. Before-preparation images and after-preparation images were then superimposed. The canal deviation during preparation was measured at 9 levels, beginning at the apex. Results. In total, 16 of 170 instruments fractured (9.4%). Nearly all preparations (98%) exhibited good taper, smooth walls, and definite apical stops. Material removal on the outer aspect of the canal was greatest near the apex (levels 1-4: 0.11-0.24 mm). The inner aspect of the canal was most instrumented at level 6 (0.23-0.27 mm). Conclusions. These findings show that both students lacking endodontic experience and experienced dentists used the rotary nickel-titanium files with success and achieved good root canal geometry.
引用
收藏
页码:714 / 718
页数:5
相关论文
共 16 条
[2]   A comparison of stainless steel Flexofiles and nickel-titanium NiTiFlex files during the shaping of simulated canals [J].
Bishop, K ;
Dummer, PMH .
INTERNATIONAL ENDODONTIC JOURNAL, 1997, 30 (01) :25-34
[3]  
Bryant ST, 1998, INT ENDOD J, V31, P275
[4]  
Bryant ST, 1998, INT ENDOD J, V31, P282
[5]   A COMPARISON OF ROOT-CANAL PREPARATIONS USING NI-TI HAND, NI-TI ENGINE-DRIVEN, AND K-FLEX ENDODONTIC INSTRUMENTS [J].
GLOSSON, CR ;
HALLER, RH ;
DOVE, SB ;
DELRIO, CE .
JOURNAL OF ENDODONTICS, 1995, 21 (03) :146-151
[6]  
KAZEMI R, 1995, J ENDODONT, V23, P216
[7]   Machining efficiency and wear resistance of nickel-titanium endodontic flies [J].
Kazemi, RB ;
Stenman, E ;
Spangberg, LSW .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1996, 81 (05) :596-602
[8]   A COMPARISON OF 4 INSTRUMENTATION TECHNIQUES ON APICAL CANAL TRANSPORTATION [J].
LUITEN, DJ ;
MORGAN, LA ;
BAUMGARTNER, JC ;
MARSHALL, JG .
JOURNAL OF ENDODONTICS, 1995, 21 (01) :26-32
[9]   Cyclic fatigue testing of nickel-titanium endodontic instruments [J].
Pruett, JP ;
Clement, DJ ;
Carnes, DL .
JOURNAL OF ENDODONTICS, 1997, 23 (02) :77-85
[10]  
SCHAFER E, 1995, ZAHNARZTL WELT, V104, P612