Spatial mapping of collagen fibril organisation in primate cornea - an X-ray diffraction investigation

被引:38
作者
Boote, C [1 ]
Dennis, S [1 ]
Meek, K [1 ]
机构
[1] Cardiff Univ, Struct Biophys Grp, Sch Optometry & Vis Sci, Cardiff, S Glam, Wales
基金
英国医学研究理事会;
关键词
cornea; collagen; lamellar structure; X-ray fibre diffraction; primate; marmoset monkey; biomechanical; light polarisation; birefringence;
D O I
10.1016/j.jsb.2003.12.009
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
New insights are presented into the collagenous structure of the primate cornea. Wide-angle X-ray diffraction was used to map the fibrillar arrangement and distribution of collagen over three common marmoset corneas. The maps provide a point of reference to help interpret data from pathological corneas or primate models of refractive surgery. The results herein disclose a circum-corneal annulus of highly aligned collagen, 0.5-1.5 mm wide. where the cornea and sclera fuse at the limbus; a feature similar to that observed in human tissue. As in humans, the annulus is not uniform, varying in width, fibril angular spread, and collagen density around its circumference. However, more centrally the marmoset cornea exhibits a preferred lamella orientation in which proportionally more fibrils are oriented along the superior-inferior corneal meridian. This observation is in striking contrast with the Situation in human cornea, where there is an orthogonal arrangement of preferentially aligned fibrils. Investigation of a further 16 corneas confirmed that approximately 33% ( +/-1%) (n = 76) of fibrils in the central marmoset cornea lie within a 45degrees sector of the superior-inferior meridian. Implications for the mechanical and optical properties of the cornea are discussed. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:359 / 367
页数:9
相关论文
共 39 条
[1]  
AGHAMOHAMMADZAD.M, 2004, IN PRESS XRAY SCATTE
[2]  
Born M., 1986, PRINCIPLES OPTICS
[3]  
Bour L. J., 1991, VISUAL OPT INSTRUMEN, V1, P310
[4]   The architecture of the corneal stroma [J].
Bron, AJ .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (04) :379-381
[5]  
Coletta NJ, 2001, INVEST OPHTH VIS SCI, V42, pS164
[6]  
Daxer A, 1997, INVEST OPHTH VIS SCI, V38, P121
[7]   NUMERICAL MODELING OF THE CORNEAS LAMELLAR STRUCTURE AND BIREFRINGENCE PROPERTIES [J].
DONOHUE, DJ ;
STOYANOV, BJ ;
MCCALLY, RL ;
FARRELL, RA .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1995, 12 (07) :1425-1438
[8]  
EHLERS N, 1966, ACTA OPHTHALMOL, V44, P620
[9]   Factors affecting the use of multifocal electroretinography to monitor function in a primate model of glaucoma [J].
Fortune B. ;
Cull G. ;
Wang L. ;
Van Buskirk E.M. ;
Cioffi G.A. .
Documenta Ophthalmologica, 2002, 105 (2) :151-178
[10]  
Hanna K D, 1992, Refract Corneal Surg, V8, P152