DNA sequence analysis by hybridization with oligonucleotide microchips: MALDI mass spectrometry identification of 5mers contiguously stacked to microchip oligonucleotides

被引:30
作者
Stomakhin, AA
Vasiliskov, VA
Timofeev, E
Schulga, D
Cotter, RJ
Mirzabekov, AD
机构
[1] Argonne Natl Lab, Biochip Technol Ctr, Argonne, IL 60439 USA
[2] Russian Acad Sci, Engelhard Inst Mol Biol, Moscow 117984, Russia
[3] Moscow Inst Phys & Technol, Dolgoprudnyi 141700, Russia
[4] Johns Hopkins Univ, Sch Med, Dept Pharmacol & Mol Sci, Middle Atlantic Mass Spectrometry Lab, Baltimore, MD 21205 USA
关键词
D O I
10.1093/nar/28.5.1193
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Matrix-assisted laser desorption ionization mass spectrometry (MALDI MS) has been applied to increase the informational output from DNA sequence analysis. It has been used to analyze DNA by hybridization with microarrays of gel-immobilized oligonucleotides extended with stacked 5mers. In model experiments, a 28 nt long DNA fragment was hybridized with 10 immobilized, overlapping 8mers. Then, in a second round of hybridization DNA-8mer duplexes were hybridized with a mixture of 10 5mers. The stability of the 5mer complex with DNA was increased to raise the melting temperature of the duplex by 10-15 degrees C as a result of stacking interaction with 8mers. Contiguous 13 bp duplexes containing an internal break were formed. MALDI MS identified one or, in some cases, two 5mers contiguously stacked to each DNA-8mer duplex formed on the microchip. Incorporating a mass label into 5mers optimized MALDI MS monitoring. This procedure enabled us to reconstitute the sequence of a model DNA fragment and identify polymorphic nucleotides. The application of MALDI MS identification of contiguously stacked 5mers to increase the length of DNA for sequence analysis is discussed.
引用
收藏
页码:1193 / 1198
页数:6
相关论文
共 24 条
[1]  
Barskii IY, 1998, J OPT TECHNOL+, V65, P938
[2]   Accessing genetic information with high-density DNA arrays [J].
Chee, M ;
Yang, R ;
Hubbell, E ;
Berno, A ;
Huang, XC ;
Stern, D ;
Winkler, J ;
Lockhart, DJ ;
Morris, MS ;
Fodor, SPA .
SCIENCE, 1996, 274 (5287) :610-614
[3]   Sequence analysis by hybridization with oligonucleotide microchip: Identification of beta-thalassemia mutations [J].
Drobyshev, A ;
Mologina, N ;
Shik, V ;
Pobedimskaya, D ;
Yershov, G ;
Mirzabekov, A .
GENE, 1997, 188 (01) :45-52
[4]   Fractionation, phosphorylation and ligation on oligonucleotide microchips to enhance sequencing by hybridization [J].
Dubiley, S ;
Kirillov, E ;
Lysov, Y ;
Mirzabekov, A .
NUCLEIC ACIDS RESEARCH, 1997, 25 (12) :2259-2265
[5]   Polymorphism analysis and gene detection by minisequencing on an array of gel-immobilized primers [J].
Dubiley, Svetlana ;
Kirillov, Eugene ;
Mirzabekov, Andrei .
NUCLEIC ACIDS RESEARCH, 1999, 27 (18)
[6]   MALDI-TOF mass spectrometric typing of single nucleotide polymorphisms with mass-tagged ddNTPs [J].
Fei, ZD ;
Ono, T ;
Smith, LM .
NUCLEIC ACIDS RESEARCH, 1998, 26 (11) :2827-2828
[7]   BASIC MATRICES FOR THE MATRIX-ASSISTED LASER-DESORPTION IONIZATION MASS-SPECTROMETRY OF PROTEINS AND OLIGONUCLEOTIDES [J].
FITZGERALD, MC ;
PARR, GR ;
SMITH, LM .
ANALYTICAL CHEMISTRY, 1993, 65 (22) :3204-3211
[8]   Parallel thermodynamic analysis of duplexes on oligodeoxyribonucleotide microchips [J].
Fotin, AV ;
Drobyshev, AL ;
Proudnikov, DY ;
Perov, AN ;
MIrzabekov, AD .
NUCLEIC ACIDS RESEARCH, 1998, 26 (06) :1515-1521
[9]   Sequencing exons 5 to 8 of the p53 gene by MALDI-TOF mass spectrometry [J].
Fu, DJ ;
Tang, K ;
Braun, A ;
Reuter, D ;
Darnhofer-Demar, B ;
Little, DP ;
O'Donnell, MJ ;
Cantor, CR ;
Köster, H .
NATURE BIOTECHNOLOGY, 1998, 16 (04) :381-384
[10]   Differential sequencing with mass spectrometry [J].
Graber, JH ;
Smith, CL ;
Cantor, CR .
GENETIC ANALYSIS-BIOMOLECULAR ENGINEERING, 1999, 14 (5-6) :215-219