Correlations between radiographic, clinical and mobility parameters after loading of oral implants with fixed partial dentures - A 2-year longitudinal study

被引:63
作者
Bragger, U
HugelPisoni, C
Burgin, W
Buser, D
Lang, NP
机构
[1] University of Berne, School of Dental Medicine, Berne
[2] University of Berne, School of Dental Medicine, CH-3010 Berne
关键词
titanium implants; non-submerged implants; clinical parameters; mobility; radiography; computer-assisted densitometric image analysis (CADIA); remodelling; functional loading; crown and bridge prosthetics;
D O I
10.1034/j.1600-0501.1996.070305.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of the present study was to correlate the changes in the peri-implant tissues occurring after functional loading of non-submerged titanium implants and assessed by radiographic, clinical and mobility measurements. 11 patients with distal extension situations received 18 implants of the ITI(R) Dental implant System. After a healing period of 3 months, the suprastructures were fabricated and seated 5 months post-surgically For the assessment of peri-implant bone changes, standardized vertical bitewing radiographs with reproducible exposure geometry were evaluated using computer assisted densitometric image analyses (CADIA) and bone height measurements. Since the radiographic evaluations were performed at mesial and distal sites only, the clinical parameters from these implant aspects were included in the analysis. Clinical periodontal parameters modified for the use around implants were obtained, damping characteristics were expressed as Periotest(R) readings and standardized radiographs were obtained at 1, 3, 6: 12 and 24 months after loading. In addition, radiographs were also taken at the start of functional loading. The data obtained from this small sample of implants demonstrated a wide range of different tissue alterations when using radiographic, clinical and mobility assessments. The parameter of probing attachment level (PAL) in combination with radiographic parameters obtained at 1, 3 and 6 months after loading were good predictors for the peri-implant tissue status at 2 years. This was shown by means of multiple stepwise regression analyses. Mobility measurements did not reveal valuable predictive information with the statistical models applied. Assessments of probing attachment levels using periodontal probes rendered information on peri-implant tissue alterations, which were closely correlated to the radiographically measurable peri-implant bone changes.
引用
收藏
页码:230 / 239
页数:10
相关论文
共 37 条
[1]   MARGINAL TISSUE-REACTIONS AT OSSEOINTEGRATED TITANIUM FIXTURES .1. A 3-YEAR LONGITUDINAL PROSPECTIVE-STUDY [J].
ADELL, R ;
LEKHOLM, U ;
ROCKLER, B ;
BRANEMARK, PI ;
LINDHE, J ;
ERIKSSON, B ;
SBORDONE, L .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1986, 15 (01) :39-52
[2]   A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW [J].
ADELL, R ;
LEKHOLM, U ;
ROCKLER, B ;
BRANEMARK, PI .
INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06) :387-416
[3]  
ADELL R, 1990, International Journal of Oral and Maxillofacial Implants, V5, P233
[4]  
AHLQVIST J, 1990, International Journal of Oral and Maxillofacial Implants, V5, P155
[5]  
Albrektsson T, 1986, Int J Oral Maxillofac Implants, V1, P11
[6]  
Bauman G R, 1992, Int J Oral Maxillofac Implants, V7, P220
[7]   COMPUTER-ASSISTED DENSITOMETRIC IMAGE-ANALYSIS IN PERIODONTAL RADIOGRAPHY - A METHODOLOGICAL STUDY [J].
BRAGGER, D ;
PASQUALI, L ;
RYLANDER, H ;
CARNES, D ;
KORNMAN, KS .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1988, 15 (01) :27-37
[8]   DIGITAL IMAGING IN PERIODONTAL RADIOGRAPHY - A REVIEW [J].
BRAGGER, U .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1988, 15 (09) :551-557
[9]   INFLUENCE OF CONTRAST ENHANCEMENT AND PSEUDOCOLOR TRANSFORMATION ON THE DIAGNOSIS WITH DIGITAL SUBTRACTION IMAGES (DSI) [J].
BRAGGER, U ;
BURGIN, W ;
MARCONI, M ;
HASLER, RU ;
LANG, NP .
JOURNAL OF PERIODONTAL RESEARCH, 1994, 29 (02) :95-102
[10]  
Bragger U, 2000, PERIODONTOL 2000, V87- 97