Mid- and long-term reproducibility of noninvasive measurements of spontaneous arterial baroreflex sensitivity in healthy volunteers

被引:47
作者
Herpin, D
Ragot, S
机构
[1] Service Cardiologie, Centre Hospitalo-Universitaire
关键词
baroreflex sensitivity; reproducibility; repeatability; photoplethysmography;
D O I
10.1016/S0895-7061(97)00115-5
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Baroreflex sensitivity (BRS) is altered in a variety of circumstances and could be considered as a marker for the prognosis of some cardiovascular diseases. The present study was designed to evaluate the reproducibility of noninvasive measures of BRS, both at mid- and at long-term. Fourteen healthy volunteers were examined on three occasions (first interval = 1 week, second interval = 1 year). Each recording was performed using a noninvasive photoplethysmographic device (Finapres 2300, Ohmeda), both in supine and standing positions. Two different methods of measurement were used: the sequences method and cross spectral analysis. The reproducibility of BRS measures was as satisfactory at mid- as at long-term for the sequences method (intraclass coefficient [ICC] = 0.87 and 0.86, respectively), but it was better at mid- than at long-term for the cross-spectral analysis (ICC = 0.85 and 0.54, respectively). The measures performed in standing position were obviously more reproducible than those made in recumbent position (ICC = 0.87 and 0.70 for the sequences method, 0.85 and 0.71 for the cross-spectral analysis, respectively). Due to the high reproducibility of these noninvasive measures, the number of patients to be included in a pharmacological study was calculated as rather small: for example, only 20 patients are required for detecting a change in upright BRS of 3 msec/mm Hg, at long-term (sequences method). Likewise, the magnitude of the regression to the mean, which has to be expected in patients selected for a follow-up study, turned out to be low: for example, <15% of the difference between the patient group mean value and the reference value, both at mid- and at long-term (standing position, sequences method). We conclude that: 1) The noninvasive measures of BRS in standing position are reproducible enough to allow longitudinal studies to be conducted over either a short or a long period; 2) The long-term reliability of the sequences method seems to be higher than that of the cross-spectral analysis; and 3) Subtle changes in SBR may be noninvasively detected within small patient groups. (C) 1997 American Journal of Hypertension, Ltd.
引用
收藏
页码:790 / 797
页数:8
相关论文
共 33 条
  • [1] ALICANDRI C, 1991, J HYPERTENS, V9, pS90
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] *BRIT STAND I, 1979, PREC TEST METH, V1
  • [4] EFFECT OF REGRESSION TO MEAN IN EPIDEMIOLOGIC AND CLINICAL STUDIES
    DAVIS, CE
    [J]. AMERICAN JOURNAL OF EPIDEMIOLOGY, 1976, 104 (05) : 493 - 498
  • [5] RELATIONSHIPS BETWEEN SHORT-TERM BLOOD-PRESSURE FLUCTUATIONS AND HEART-RATE-VARIABILITY IN RESTING SUBJECTS .1. A SPECTRAL-ANALYSIS APPROACH
    DEBOER, RW
    KAREMAKER, JM
    STRACKEE, J
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1985, 23 (04) : 352 - 358
  • [6] BAROREFLEX SENSITIVITY, BUT NOT HEART-RATE-VARIABILITY, IS REDUCED IN PATIENTS WITH LIFE-THREATENING VENTRICULAR ARRHYTHMIAS LONG AFTER MYOCARDIAL-INFARCTION
    DEFERRARI, GM
    LANDOLINA, M
    MANTICA, M
    MANFREDINI, R
    SCHWARTZ, PJ
    LOTTO, A
    [J]. AMERICAN HEART JOURNAL, 1995, 130 (03) : 473 - 480
  • [7] Dibner Dunlap M. E., 1996, J AM COLL CARDIOL, V27, P358
  • [8] REPRODUCIBILITY OF NONINVASIVE MEASUREMENT AND OF SHORT-TERM VARIABILITY OF BLOOD-PRESSURE AND HEART-RATE IN HEALTHY-VOLUNTEERS
    DIMIERDAVID, L
    BILLON, N
    COSTAGLIOLA, D
    JAILLON, P
    FUNCKBRENTANO, C
    [J]. BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1994, 38 (02) : 109 - 115
  • [9] A NEW NONINVASIVE STATISTICAL-METHOD TO ASSESS THE SPONTANEOUS CARDIAC BAROREFLEX IN HUMANS
    DUCHER, M
    FAUVEL, JP
    GUSTIN, MP
    CERUTTI, C
    NAJEM, R
    CUISINAUD, G
    LAVILLE, M
    POZET, N
    PAULTRE, CZ
    [J]. CLINICAL SCIENCE, 1995, 88 (06) : 651 - 655
  • [10] LOW AMBIENT-TEMPERATURE INCREASES BAROREFLEX-GOVERNED SYMPATHETIC OUTFLOW TO MUSCLE VESSELS IN HUMANS
    FAGIUS, J
    KAY, R
    [J]. ACTA PHYSIOLOGICA SCANDINAVICA, 1991, 142 (02): : 201 - 209