Full-scale experimental investigation of repair of reinforced concrete interstate bridge using CFRP materials

被引:86
作者
Aidoo, John [1 ]
Harries, Kent A.
Petrou, Michael F.
机构
[1] Rose Hulman Inst Technol, Dept Civil Engn, Terre Haute, IN 47803 USA
[2] Univ Pittsburgh, Dept Civil & Environm Engn, Pittsburgh, PA 15261 USA
[3] Univ Cyprus, Dept Civil & Environm Engn, Nicosia, Cyprus
关键词
bonding; fatigue; fiber reinforced polymers; composite materials; full-scale tests; retrofitting; bridges; highway;
D O I
10.1061/(ASCE)1084-0702(2006)11:3(350)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An experimental study is presented of the behavior of eight reinforced concrete bridge girders taken from a decommissioned Interstate bridge and retrofitted with three different carbon-fiber-reinforced polymer (CFRP) systems. Specimens were subjected to monotonic loading to failure with and without significant fatigue conditioning. Experimental observations indicated that intermediate crack-induced debonding was the dominant failure mode for monotonically loaded beams and that degradation of the CFRP-to-concrete interface was caused by fatigue conditioning. Conventional adhesive applied and near-surface mounted (NSM) CFRP systems behaved well under monotonic loads, with the NSM system exhibiting significantly greater ductility. Powder actuated fastener applied retrofit was observed to be less efficient, requiring a relative slip of the CFRP in. order to engage the shear transfer mechanism of the fasteners. The application of current accepted design guidelines for FRP retrofit indicated that guidelines aimed at mitigating debonding failure appear to be appropriately conservative under monotonic loading conditions; however, a significant additional reduction in CFRP strain limits is required to account for even small levels of fatigue loading.
引用
收藏
页码:350 / 358
页数:9
相关论文
共 15 条
[1]  
*ACI, 2002, 440 ACI
[2]   Fatigue behavior of carbon fiber reinforced polymer-strengthened reinforced concrete bridge girders [J].
Aidoo, J ;
Harries, KA ;
Petrou, MF .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2004, 8 (06) :501-509
[3]  
American Association of State Highway and Transportation Officials (AASHTO), 1996, STAND SPEC HIGHW BRI
[4]  
Barnes R., 1999, J COMPOS CONSTR, V3, P63, DOI DOI 10.1061/(ASCE)1090-0268(1999)3:2(63)
[5]  
Buyukozturk O., 1998, J COMPOS CONSTR, V2, P138, DOI DOI 10.1061/(ASCE)1090-0268(1998)2:3(138)
[6]   An experimental study of the failure modes of reinforced concrete beams strengthened with prestressed carbon composite plates [J].
Garden, HN ;
Hollaway, LC .
COMPOSITES PART B-ENGINEERING, 1998, 29 (04) :411-424
[7]  
GULBRANDSEN PW, 2003, TENSILE BEARING TEST
[8]  
*HILT INC, 2002, POWD ACT FAST SYST D
[9]   Delamination failure in concrete beams retrofitted with a bonded plate [J].
Leung, CKY .
JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2001, 13 (02) :106-113
[10]  
*LLC FYF CO, 2000, TYF SYST PROD LIT