Is referencing the posterior condyles sufficient to achieve a rectangular flexion gap in total knee arthroplasty?

被引:61
作者
Schnurr, Christoph [1 ]
Nessler, Jochen [1 ]
Koenig, Dietmar Pierre [1 ]
机构
[1] Rhein Klin Orthopadie Viersen, D-41749 Viersen, Germany
关键词
FEMORAL ROTATIONAL ALIGNMENT; TRANSEPICONDYLAR AXIS; COMPONENT ROTATION; PATELLAR TRACKING; EPICONDYLAR AXIS; REPRODUCIBILITY; COMPLICATIONS; PROSTHESIS; NAVIGATION; LANDMARKS;
D O I
10.1007/s00264-008-0656-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Femoral malrotation in total knee arthroplasty causes flexion gap instability. Conventional instruments mostly reference the posterior condylar angle (PCA). The aim of this study was to verify whether the computer-navigated flexion gap (GAP) method produces a rectangular flexion gap and if a balanced flexion gap could also be achieved by referencing the PCA. A total of 100 knee prostheses were analysed using the navigated GAP method, and flexion gap symmetry along with femoral rotation were recorded. The GAP technique resulted in a rectangular flexion gap with adequate femoral rotational alignment. If the PCA technique had been used, only 51% of the femoral components would have been implanted in correct femoral rotation; the remaining 49% would have implanted with flexion gap instability. The GAP technique produces a rectangular flexion gap. The referencing of the PCA was shown to be less reliable. Thus, modern knee prosthesis instrumentation should not base femoral rotation solely on the PCA.
引用
收藏
页码:1561 / 1565
页数:5
相关论文
共 25 条
[1]
BERGER RA, 1993, CLIN ORTHOP RELAT R, P40
[2]
Malrotation causing patellofemoral complications after total knee arthroplasty [J].
Berger, RA ;
Crossett, LS ;
Jacobs, JJ ;
Rubash, HE .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (356) :144-153
[3]
LONG-TERM COMPLICATIONS AFTER TOTAL KNEE ARTHROPLASTY WITH OR WITHOUT RESURFACING OF THE PATELLA [J].
BOYD, AD ;
EWALD, FC ;
THOMAS, WH ;
POSS, R ;
SLEDGE, CB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (05) :674-681
[4]
Churchill DL, 1998, CLIN ORTHOP RELAT R, P111
[5]
Rotational malalignment of the femoral component in total knee arthroplasty [J].
Fehring, TK .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2000, (380) :72-79
[6]
The posterior condylar angle in osteoarthritic knees [J].
Griffin, FM ;
Insall, JN ;
Scuderi, GR .
JOURNAL OF ARTHROPLASTY, 1998, 13 (07) :812-815
[7]
Bone landmarks are more reliable than tensioned gaps in TKA component alignment [J].
Hanada, Hirofumi ;
Whiteside, Leo A. ;
Steiger, Jerry ;
Dyer-, Paul ;
Naito, Masatoshi .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (462) :137-142
[8]
HUNGERFORD DS, 1985, CLIN ORTHOP RELAT R, P23
[9]
Low reproducibility of the intra-operative measurement of the transepicondylar axis during total knee replacement [J].
Jenny, JY ;
Boeri, C .
ACTA ORTHOPAEDICA SCANDINAVICA, 2004, 75 (01) :74-77
[10]
Interindividual reproducibility in perioperative rotational alignment of femoral components in knee prosthetic surgery using the transepicondylar axis [J].
Jerosch, J ;
Peuker, E ;
Philipps, B ;
Filler, T .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2002, 10 (03) :194-197