The thermal conductivity of liquid 1,1,1,2-tetrafluoroethane (HFC 134a)

被引:17
作者
Gurova, AN
Mardolcar, UV
deCastro, CAN
机构
[1] UNIV LISBON,FAC CIENCIAS,CTR CIENCIA & TECNOL MAT,P-1700 LISBON,PORTUGAL
[2] UNIV LISBON,FAC CIENCIAS,ICAT,P-1700 LISBON,PORTUGAL
[3] INST SUPER TECN,DEPT FIS,P-1096 LISBON,PORTUGAL
关键词
HFC; 134a; high pressure; 1,1,1,2-tetrafluoroethane; thermal conductivity;
D O I
10.1007/BF02575250
中图分类号
O414.1 [热力学];
学科分类号
摘要
The thermal conductivity of HFC 134a was measured in the liquid phase with the polarized transient hot-wire technique. The experiments were performed at temperatures from 213 to 293 K at pressures up to 20 MPa. The data were analyzed to obtain correlations in terms of density and pressure. This study is part of an international project coordinated by the Subcommittee on Transport Properties of Commission 1.2 of IUPAC, conducted to investigate the large discrepancies between the results reported by various authors for the transport properties of HFC 134a, using samples of different origin. Two samples of HFC 134a from different sources have been used. The thermal conductivity of the first sample was measured along the saturation line as a function of temperature and the data were presented earlier. The thermal conductivity of the second one, the round-robin sample, was measured as a function of pressure and temperature. These data were extrapolated to the saturation line and compared with the data obtained, previously in order to demonstrate the importance of the sample origin and their real purity. The accuracy of the measurements is estimated to be 0.5%. Finally, the results are compared with the existing literature data.
引用
收藏
页码:1077 / 1087
页数:11
相关论文
共 20 条
[1]   STATUS OF THE ROUND-ROBIN ON THE TRANSPORT-PROPERTIES OF R134A [J].
ASSAEL, MJ ;
NAGASAKA, Y ;
DECASTRO, CAN ;
PERKINS, RA ;
STROM, K ;
VOGEL, E ;
WAKEHAM, WA .
INTERNATIONAL JOURNAL OF THERMOPHYSICS, 1995, 16 (01) :63-78
[2]   MEASUREMENTS OF THE THERMAL-CONDUCTIVITY OF R22, R123, AND R134A IN THE TEMPERATURE-RANGE 250-340-K AT PRESSURES UP TO 30 MPA [J].
ASSAEL, MJ ;
KARAGIANNIDIS, E .
INTERNATIONAL JOURNAL OF THERMOPHYSICS, 1993, 14 (02) :183-197
[3]  
ASSAEL MJ, 1997, INT J THERMOPHYS
[4]  
Carslaw H. S., 1959, CONDUCTION HEAT SOLI
[5]   RADIATIVE HEAT-TRANSFER IN TRANSIENT HOT-WIRE MEASUREMENTS OF THERMAL-CONDUCTIVITY [J].
DECASTRO, CAN ;
PERKINS, RA ;
RODER, HM .
INTERNATIONAL JOURNAL OF THERMOPHYSICS, 1991, 12 (06) :985-997
[6]   THERMAL-CONDUCTIVITY OF THE NEW REFRIGERANTS R134A, R152A, AND R123 MEASURED BY THE TRANSIENT HOT-WIRE METHOD [J].
GROSS, U ;
SONG, YW ;
HAHNE, E .
INTERNATIONAL JOURNAL OF THERMOPHYSICS, 1992, 13 (06) :957-983
[7]  
GUROVA A, 1994, HIGH TEMP HIGH PRESS, V26, P25
[8]  
GUROVA AN, 1994, THERMAL CONDUCTIVITY, V22, P189
[9]  
*JAP ASS REFR JAP, 1991, THERM PROP ENV ACC F, P140
[10]  
Kim D.S., 1994, THERMAL CONDUCTIVITY, V22, P177