A new artifact-free device for frameless, magnetic resonance imaging-guided stereotactic procedures

被引:26
作者
Bernays, RL
Kollias, SS
Khan, N
Romanowski, B
Yonekawa, Y
机构
[1] Univ Zurich Hosp, Dept Neurosurg, CH-8091 Zurich, Switzerland
[2] Univ Zurich Hosp, Dept Neuroradiol, CH-8091 Zurich, Switzerland
[3] Univ Zurich Hosp, Dept Radiol, CH-8091 Zurich, Switzerland
关键词
frameless stereotaxy; image-guided surgery; instrumentation; interventional magnetic resonance imaging; magnetic resonance imaging; neuronavigation;
D O I
10.1093/neurosurgery/46.1.112
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: A new, artifact-free, nonobstructive device was required for planning, guiding, and performing stereotactic procedures in an open magnetic resonance imaging (MRI) system (Signa SP; General Electric, Milwaukee, WI). DESCRIPTION OF INSTRUMENTATION: We devised an MRI-compatible instrument set that was adapted to an optical triangulation system (FlashPoint System; Image Guided Technologies, Boulder, CO) and consisted of a Pathfinder for planning burr holes and trajectories and a Snapper-Stereoguide for guiding minimally invasive instruments such as biopsy cannulae, endoscopes, and laser fibers. The instruments were composed of biocompatible plastic (polyacetal). During evaluation, special attention was paid to safety, accuracy, operation times, and susceptibility artifacts of the system. RESULTS: The first 20 stereotactic procedures performed in the open MRI scanner included 15 biopsies, 1 cyst and 3 abscess evacuations, and 1 endoscopic procedure for treatment of multiseptate hydrocephalus. There were no adverse outcomes, and all biopsies were diagnostic. The frameless stereotactic system in combination with the FlashPoint System proved to be accurate, with a mean error of 1.5 mm. The biopsy devices did not cause any susceptibility artifacts. Highly vascularized structures were clearly visible and were included in the trajectory planning. With experience, the procedure time was reduced to less than 1 hour. CONCLUSION: This device was found to be quite helpful for planning and guiding; stereotactic procedures in the open MRI scanner. Nearly real-time planning and monitoring of stereotactic procedures and the positional accuracy of the system make the open MRI system a definite improvement, compared with conventional stereotactic systems.
引用
收藏
页码:112 / 116
页数:5
相关论文
共 17 条
  • [1] ANZAI Y, 1995, AM J NEURORADIOL, V16, P39
  • [2] ULTRASOUND-GUIDED STEREOTAXIC BIOPSY USING A NEW APPARATUS
    BERGER, MS
    [J]. JOURNAL OF NEUROSURGERY, 1986, 65 (04) : 550 - 554
  • [3] Bettag M, 1991, Acta Neurochir Suppl (Wien), V52, P81
  • [4] De Salles Antonio, 1997, P108
  • [5] DILORENZO N, 1991, J NEUROSURG, V75, P763
  • [6] Farahani Keyvan, 1997, P98
  • [7] BIOCOMPATIBILITY OF DELRIN 150 - A CREEP-RESISTANT POLYMER FOR TOTAL JOINT PROSTHESES
    FISTER, JS
    MEMOLI, VA
    GALANTE, JO
    ROSTOKER, W
    URBAN, RM
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1985, 19 (05): : 519 - 533
  • [8] BIOLOGICAL RESPONSE TO CHOPPED-CARBON-FIBER-REINFORCED PEEK
    JOCKISCH, KA
    BROWN, SA
    BAUER, TW
    MERRITT, K
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1992, 26 (02): : 133 - 146
  • [9] Mapping of the cortical motor hand area with functional MR imaging and MR imaging-guided laser-induced interstitial thermotherapy of brain tumors - Work in progress
    Kahn, T
    Schwabe, B
    Bettag, M
    Harth, T
    Ulrich, F
    Rassek, M
    Schwarzmaier, HJ
    Modder, U
    [J]. RADIOLOGY, 1996, 200 (01) : 149 - 157
  • [10] Photodynamic therapy in neurosurgery: A review
    Kostron, H
    Obwegeser, A
    Jakober, R
    [J]. JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY B-BIOLOGY, 1996, 36 (02) : 157 - 168