Comparison of frequency doubling perimetry with Humphrey visual field analysis in a glaucoma practice

被引:100
作者
Burnstein, Y [1 ]
Ellish, NJ [1 ]
Magbalon, M [1 ]
Higginbotham, EJ [1 ]
机构
[1] Univ Maryland, Sch Med, Dept Ophthalmol, Baltimore, MD 21201 USA
关键词
D O I
10.1016/S0002-9394(99)00364-5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To determine the sensitivity and specificity of frequency doubling perimetry with Humphrey visual field testing used as the gold standard. METHODS: Frequency doubling perimetry and Humphrey visual field testing (24-2) were performed on 29 consecutive patients in a glaucoma practice. Data for the right eye were used to calculate sensitivity, specificity, and receiver operating characteristic curves. RESULTS: For the frequency doubling perimetry in screening mode, and with an abnormal glaucoma hemifield test used as the gold standard, the area under the receiver operating characteristic curve was 89.3%, 81.5%, or 75.0% for the presence of mild, moderate, or severe relative defects, respectively. Similar results were found with the use of mean deviation (P < .05) to define Humphrey visual field defects. For frequency doubling perimetry in threshold mode, the area under the receiver operating characteristic curve was 93.4% with the presence of any defect (P < .05) used as the criterion for an abnormal case, and an abnormal glaucoma hemifield test as the gold standard. In all cases, the threshold mode detected defects better than the screening mode. CONCLUSIONS: Frequency doubling perimetry showed a high sensitivity and specificity for detecting visual field abnormalities, especially when threshold strategies were used. (C) 2000 by Elsevier Science Inc. All rights reserved.
引用
收藏
页码:328 / 333
页数:6
相关论文
共 12 条
[1]  
Anderson DR., 1992, AUTOMATED STATIC PER
[2]  
BECK RW, 1985, OPHTHALMOLOGY, V92, P77
[3]  
Johnson CA, 1997, INVEST OPHTH VIS SCI, V38, P413
[4]   NON-LINEAR VISUAL RESPONSES TO FLICKERING SINUSOIDAL GRATINGS [J].
KELLY, DH .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1981, 71 (09) :1051-1055
[5]  
MADDESS T, 1992, CLIN VISION SCI, V7, P371
[6]   Identification of glaucoma-related visual field abnormality with the screening protocol of frequency doubling technology [J].
Quigley, HA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 125 (06) :819-829
[7]  
QUIGLEY HA, 1988, OPHTHALMOLOGY, V95, P357
[8]  
RITCH R, 1996, GLAUCOMAS, pR17
[9]   Short-wavelength automated perimetry and motion automated perimetry in patients with glaucoma [J].
Sample, PA ;
Bosworth, CF ;
Weinreb, RN .
ARCHIVES OF OPHTHALMOLOGY, 1997, 115 (09) :1129-1133
[10]   Clinical classification of glaucomatous visual field loss by frequency doubling perimetry [J].
Sponsel, WE ;
Arango, S ;
Trigo, Y ;
Mensah, J .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 125 (06) :830-836