A PVC-graphite composite electrode for electroanalytical use. Preparation and some applications

被引:51
作者
Albertus, F
Llerena, A
Alpizar, J
Cerda, V
Luque, M
Rios, A
Valcarcel, M
机构
[1] UNIV CORDOBA,FAC SCI,DEPT ANALYT CHEM,E-14004 CORDOBA,SPAIN
[2] UNIV HAVANA,FAC CHEM,DEPT ANALYT CHEM,HAVANA 10400,CUBA
[3] UNIV ILLES BALEARS,DEPT CHEM,PALMA DE MALLORCA,SPAIN
关键词
composite electrode; PVC-graphite; voltammetry; stripping; flow amperometric detection;
D O I
10.1016/S0003-2670(97)81608-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The preparation of a new carbon composite electrode, constructed from PVC-graphite compressed mixtures, is described. The performance as a working electrode for oxidative voltammetry was studied with cyclic voltammetry on hexacyanoferrate(III) in 1M HCl. Catechol and hydroquinone were also used as model test systems. Well defined current potential curves are reported. Examples of applications in anodic stripping voltammetry (ASV), including the formation of mercury films are presented. The possible use of PVC-graphite electrodes placed in a typical wall-jet flow cell as amperometric detectors was also examined by employing catechol as the test analyte. The PVC-graphite composite exhibits favorable qualities as an electrode material, with respect to its mechanical resistance, very low cost, simple preparation and easy renewal of the electrode surface. The results show a satisfactory combination of good electrode kinetics, with small background current, and relatively reproducible signals. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:23 / 32
页数:10
相关论文
共 26 条
  • [1] GRAPHITE-EPOXY MERCURY THIN-FILM WORKING ELECTRODE FOR ANODIC-STRIPPING VOLTAMMETRY
    ANDERSON, JE
    TALLMAN, DE
    [J]. ANALYTICAL CHEMISTRY, 1976, 48 (01) : 209 - 212
  • [2] [Anonymous], [No title captured]
  • [3] [Anonymous], 1976, ELECTROCHEMICAL STRI
  • [4] BARD AJ, 1980, ELECTROCHEMICAL METH, P14
  • [5] Brainina K. Z., 1974, STRIPPING VOLTAMMETR
  • [6] SENSORS AND SAMPLE PREPARATION IN STRIPPING VOLTAMMETRY
    BRAININA, KZ
    [J]. ANALYTICA CHIMICA ACTA, 1995, 305 (1-3) : 146 - 153
  • [7] New materials for electrochemical sensing .1. Rigid conducting composites
    Cespedes, F
    MartinezFabregas, E
    Alegret, S
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1996, 15 (07) : 296 - 304
  • [8] Dryhurst Glenn, 1984, LAB TECHNIQUES ELECT
  • [9] DEVELOPMENT OF GRAPHITE-POLY(TETRAFLUOROETHYLENE) COMPOSITE ELECTRODES - VOLTAMMETRIC DETERMINATION OF THE HERBICIDES THIRAM AND DISULFIRAM
    FERNANDEZ, C
    REVIEJO, AJ
    PINGARRON, JM
    [J]. ANALYTICA CHIMICA ACTA, 1995, 305 (1-3) : 192 - 199
  • [10] VOLTAMMETRIC STUDIES OF COMPOSITE CERAMIC CARBON WORKING ELECTRODES
    GUN, G
    TSIONSKY, M
    LEV, O
    [J]. ANALYTICA CHIMICA ACTA, 1994, 294 (03) : 261 - 270