Biodegradable arrows for arthroscopic repair of meniscal tears

被引:10
作者
Al-Othman, AA [1 ]
机构
[1] King Fahd Univ Hosp, Al Khobar 31952, Saudi Arabia
关键词
D O I
10.1007/s00264-002-0359-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Thirty-two meniscal tears in 32 patients were repaired using biodegradable meniscus arrows. The tears were fixed arthroscopically using an all-inside technique. Ten patients had a simultaneous anterior cruciate ligament (ACL) reconstruction. The period of follow-up was an average of 25 (10-40) months. Twenty-six patients were clinically stable and asymptomatic at follow-up. Six patients were considered clinically unstable and all had associated ACL reconstruction and required a repeat arthroscopy. Two meniscal repairs failed to heal, and the broken meniscus arrow was retrieved arthroscopically 6 months after the primary operation. In four cases the meniscal tear healed completely (two cases) or partially. Otherwise, there were no objective signs of complications. The use of meniscus arrows is a simple, safe, and reliable method for repair of properly selected meniscal tears.
引用
收藏
页码:247 / 249
页数:3
相关论文
共 18 条
[1]
The arrow versus horizontal suture in arthroscopic meniscus repair - A prospective randomized study with arthroscopic evaluation [J].
Albrecht-Olsen, P ;
Kristensen, G ;
Burgaard, P ;
Joergensen, U ;
Toerholm, C .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 1999, 7 (05) :268-273
[2]
Albrecht-Olsen P, 1993, Knee Surg Sports Traumatol Arthrosc, V1, P104, DOI 10.1007/BF01565462
[3]
Failure strength of a new meniscus arrow repair technique: Biomechanical comparison with horizontal suture [J].
AlbrechtOlsen, P ;
Lind, T ;
Kristensen, G ;
Falkenberg, B .
ARTHROSCOPY, 1997, 13 (02) :183-187
[4]
Biomechanical investigations of different meniscal repair implants in comparison with horizontal sutures on human meniscus [J].
Becker, R ;
Schröder, M ;
Stärke, C ;
Urbach, D ;
Nebelung, W .
ARTHROSCOPY, 2001, 17 (05) :439-444
[5]
Pull-out strength and stiffness of meniscal repair using absorbable arrows or Ti-Cron vertical and horizontal loop sutures [J].
Boenisch, UW ;
Faber, KJ ;
Ciarelli, M ;
Steadman, JR ;
Arnoczky, SP .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1999, 27 (05) :626-631
[6]
CADER SJ, 1999, ARTHROSCOPY, V15, P652
[7]
COREA JR, 1994, KNEE SURG SPORT TR A, V2, P70, DOI DOI 10.1007/BF01476474
[8]
LONG-TERM RESULTS OF ARTHROSCOPIC MENISCAL REPAIR - AN ANALYSIS OF ISOLATED TEARS [J].
EGGLI, S ;
WEGMULLER, H ;
KOSINA, J ;
HUCKELL, C ;
JAKOB, RP .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1995, 23 (06) :715-720
[9]
Subcutaneous migration of meniscal arrows after failed meniscus repair - A report of two cases [J].
Ganko, A ;
Engebretsen, L .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2000, 28 (02) :252-253
[10]
Cystic hematoma formation following use of a biodegradable arrow for meniscal repair [J].
Hechtman, KS ;
Uribe, JW .
ARTHROSCOPY, 1999, 15 (02) :207-210