Analytical Chemistry of Nitric Oxide

被引:259
作者
Hetrick, Evan M. [1 ]
Schoenfisch, Mark H. [1 ]
机构
[1] Univ N Carolina, Dept Chem, Chapel Hill, NC 27599 USA
基金
美国国家卫生研究院;
关键词
reactive nitrogen species; Griess assay; chemiluminescence; electron paramagnetic resonance spectroscopy; electrochemical sensors; LASER-INDUCED FLUORESCENCE; IN-VIVO DETECTION; PARAMAGNETIC-RESONANCE SPECTROSCOPY; QUARTZ-CRYSTAL MICROBALANCE; GRIESS REACTION; SPECTROPHOTOMETRIC DETERMINATION; ELECTROCHEMICAL DETECTION; BIOLOGICAL-SYSTEMS; NO DETECTION; GAS SENSOR;
D O I
10.1146/annurev-anchem-060908-155146
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Nitric oxide (NO) is the focus of intense research primarily because of its wide-ranging biological and physiological actions. To understand its origin, activity and regulation, accurate and precise measurement techniques are needed. Unfortunately, analytical assays for monitoring NO are challenged by NO'S Unique chemical and physical properties, including its reactivity, rapid diffusion, and short half-life. Moreover, NO concentrations may span the picomolar-to-micromolar range ill physiological milieus, requiring techniques with wide dynamic response ranges. Despite such challenges, many analytical techniques have emerged for the detection of NO. Herein, we review the most common spectroscopic and electrochemical methods, with a focus oil the underlying mechanism of each technique and oil approaches that have been coupled with modern analytical measurement tools to create novel NO sensors.
引用
收藏
页码:409 / 433
页数:25
相关论文
共 161 条
[1]   Optical biosensing of gaseous nitric oxide using spin-coated sol-gel thin films [J].
Aylott, JW ;
Richardson, DJ ;
Russell, DA .
CHEMISTRY OF MATERIALS, 1997, 9 (11) :2261-2263
[2]   Mid-infrared quantum cascade laser based off-axis integrated cavity output spectroscopy for biogenic nitric oxide detection [J].
Bakhirkin, YA ;
Kosterev, AA ;
Roller, C ;
Curl, RF ;
Tittel, FK .
APPLIED OPTICS, 2004, 43 (11) :2257-2266
[3]   Development and cellular applications of fiber optic nitric oxide sensors based on a gold-adsorbed fluorophore [J].
Barker, SLR ;
Kopelman, R .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :4902-4906
[4]   Fiber-optic nitric oxide-selective biosensors and nanosensors [J].
Barker, SLR ;
Kopelman, R ;
Meyer, TE ;
Cusanovich, MA .
ANALYTICAL CHEMISTRY, 1998, 70 (05) :971-976
[5]   Ratiometric and fluorescence lifetime-based biosensors incorporating cytochrome c′ and the detection of extra- and intracellular macrophage nitric oxide [J].
Barker, SLR ;
Clark, HA ;
Swallen, SF ;
Kopelman, R ;
Tsang, AW ;
Swanson, JA .
ANALYTICAL CHEMISTRY, 1999, 71 (09) :1767-1772
[6]  
Bates J.N., 1992, NEUROPROTOCOLS, V1, P141
[7]   Electrochemical nitric oxide sensors for biological samples - Principle, selected examples and applications [J].
Bedioui, F ;
Villeneuve, N .
ELECTROANALYSIS, 2003, 15 (01) :5-18
[8]   Apoplastic synthesis of nitric oxide by plant tissues [J].
Bethke, PC ;
Badger, MR ;
Jones, RL .
PLANT CELL, 2004, 16 (02) :332-341
[9]   Application of a compact all solid-state laser system to the in situ detection of atmospheric OH, HO2, NO and IO by laser-induced fluorescence [J].
Bloss, WJ ;
Gravestock, TJ ;
Heard, DE ;
Ingham, T ;
Johnson, GP ;
Lee, JD .
JOURNAL OF ENVIRONMENTAL MONITORING, 2003, 5 (01) :21-28
[10]   Nitric oxide and the immune response [J].
Bogdan, C .
NATURE IMMUNOLOGY, 2001, 2 (10) :907-916