Characterizing solute binding to macroporous ion exchange membrane adsorbers using confocal laser scanning microscopy

被引:39
作者
Wickramasinghe, S. R. [1 ]
Carlson, J. O.
Teske, C.
Hubbuch, J.
Ulbricht, M.
机构
[1] Colorado State Univ, Dept Biol & Chem Engn, Ft Collins, CO 80523 USA
[2] Univ Duisburg Gesamthsch, Lehrstuhl Tech Chemie 2, D-45117 Essen, Germany
[3] Nanyang Technol Univ, Div Chem & Biomol Engn, Singapore 637722, Singapore
[4] Colorado State Univ, Dept Microbiol Immunol & Pathol, Ft Collins, CO 80523 USA
[5] Forschungszentrum Julich, Inst Biotechnol 2, D-52425 Julich, Germany
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
Aedes aegypti densonucleosis virus; membrane adsorber; ion exchange membranes; confocal laser scanning microscopy; virus purification;
D O I
10.1016/j.memsci.2006.04.032
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Purification of virus particles for viral vaccines and applications of gene therapy is a major large scale separations challenge. Here adsorption of Aedes aegypti densonucleosis virus by anion and cation exchange membranes has been investigated. As the virus particles are viable at pH values above and below their isoelectric point, adsorption by anion and cation exchange membranes is feasible. The capacity of the membranes for virus particles is orders of magnitude less than the manufacturer's stated capacity for model proteins such as BSA and lysozyme indicating that binding patterns are very different for different sized solutes. In order to visualize solute binding confocal laser scanning microscopy (CLSM) has been used to observe binding of thyroglobulin, BSA and lysozyme to cation exchange membranes. The results are in qualitative agreement with the measured capacities for virus particles, BSA and lysozyme. However, the results also indicate that the binding patterns for thyroglobulin, BSA and lysozyme are very different. It appears that compared to lysozyme and BSA, only a few pores are available for thyroglobulin binding, in agreement with the much lower measured binding capacity for thyroglobulin compared to BSA and lysozyme. Therefore, CLSM could be a useful visualization technique when designing membranes with optimized pore structures. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:609 / 618
页数:10
相关论文
共 30 条
[1]  
Belter P. A., 1988, BIOSEPARATIONS DOWNS
[2]   Comparison of microporous membrane morphologies using confocal scanning laser microscopy [J].
Charcosset, C ;
Bernengo, JC .
JOURNAL OF MEMBRANE SCIENCE, 2000, 168 (1-2) :53-62
[3]   Calculation of flow and solute deposition through three-dimensional reconstructed model of microporous membranes [J].
Charcosset, C ;
Yousefian, F ;
Thovert, JF ;
Adler, PM .
DESALINATION, 2002, 145 (1-3) :133-138
[4]   Characterization of microporous membranes using confocal scanning laser microscopy in fluorescence mode [J].
Charcosset, C ;
Bernengo, JC .
EUROPEAN PHYSICAL JOURNAL-APPLIED PHYSICS, 2000, 12 (03) :195-199
[5]   PROTEIN-A IMMUNOAFFINITY HOLLOW-FIBER MEMBRANES FOR IMMUNOGLOBULIN-G PURIFICATION - EXPERIMENTAL CHARACTERIZATION [J].
CHARCOSSET, C ;
SU, ZG ;
KAROOR, S ;
DAUN, G ;
COLTON, CK .
BIOTECHNOLOGY AND BIOENGINEERING, 1995, 48 (04) :415-427
[6]   Characterization of microporous membrane morphology using confocal scanning laser microscopy [J].
Charcosset, C ;
Cherfi, A ;
Bernengo, JC .
CHEMICAL ENGINEERING SCIENCE, 2000, 55 (22) :5351-5358
[7]   PROTEIN EXTRACTIONS WITH HOLLOW FIBERS [J].
DAHURON, L ;
CUSSLER, EL .
AICHE JOURNAL, 1988, 34 (01) :130-136
[8]   Large-scale membrane adsorbers [J].
Demmer, W ;
Nussbaumer, D .
JOURNAL OF CHROMATOGRAPHY A, 1999, 852 (01) :73-81
[9]   Evaluation of an ion-exchange membrane for the purification of plasmid DNA [J].
Endres, HN ;
Johnson, JAC ;
Ross, CA ;
Welp, JK ;
Etzel, MR .
BIOTECHNOLOGY AND APPLIED BIOCHEMISTRY, 2003, 37 :259-266
[10]   Protein separation using membrane chromatography: opportunities and challenges [J].
Ghosh, R .
JOURNAL OF CHROMATOGRAPHY A, 2002, 952 (1-2) :13-27