Uncovering new challenges in bio-analysis with ToF-SIMS

被引:26
作者
Fletcher, John S. [1 ]
Henderson, Alex [1 ]
Biddulph, Gregory X. [1 ]
Vaidyanathan, Seetharaman [1 ]
Lockyer, Nicholas P. [1 ]
Vickerman, John C. [1 ]
机构
[1] Univ Manchester, Manchester Interdisciplinary Bioctr, Manchester M1 7DN, Lancs, England
基金
英国工程与自然科学研究理事会; 英国生物技术与生命科学研究理事会;
关键词
D O I
10.1016/j.apsusc.2008.05.253
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The introduction of cluster ion beams for routine SIMS analysis has greatly improved the prospects for characterising biological samples. The ultimate quality of the secondary ion image remains limited by the efficiency of the primary beam. Without overcoming the low ionisation probabilities associated with SIMS, the highest lateral resolution available for molecular imaging becomes limited by the statistical probability of any ions being generated from the area of the pixel. C-60(+) primary ions are currently the most efficient available for routine analysis but although commercial systems have been demonstrated to produce spot sizes under 200 nm, focusing the beam produced in such electron impact sources results in rather low ion currents. The time scale for such high lateral resolution analysis can become impractical on conventional time-of-flight instruments. Molecular depth pro. ling capability has been revealed using SF5+ and C-60(+) ion beams and recent work has advanced the technique by combining the pro. ling and imaging abilities of these high efficiency projectiles to generate 3D molecular maps of biological systems. In this paper we discuss the challenges associated with 2D and 3D bio-analysis with emphasis on how instrumental advances aid such investigations yet demonstrating the obstacles that need to be overcome using a range of model and real world biological samples. We discuss complications with the biological matrix, challenges in manipulating and visualising the data and look at how instrumental advantages might aid the routine generation of these 3D molecular maps. (C) 2008 Elsevier B. V. All rights reserved.
引用
收藏
页码:1264 / 1270
页数:7
相关论文
共 31 条
[1]   Lipid imaging in the zebra finch brain with secondary ion mass spectrometry [J].
Amaya, Kensey R. ;
Monroe, Eric B. ;
Sweedler, Jonathan V. ;
Clayton, David F. .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2007, 260 (2-3) :121-127
[2]   Properties of C84 and C24H12 molecular ion sources for routine TOF-SIMS analysis [J].
Biddulph, Gregory X. ;
Piwowar, Alan M. ;
Fletcher, John S. ;
Lockyer, Nicholas P. ;
Vickerman, John C. .
ANALYTICAL CHEMISTRY, 2007, 79 (19) :7259-7266
[3]   Biological tissue imaging with time-of-flight secondary ion mass spectrometry and cluster ion sources [J].
Brunelle, A ;
Touboul, D ;
Laprévote, O .
JOURNAL OF MASS SPECTROMETRY, 2005, 40 (08) :985-999
[4]   Depth profiling of peptide films with TOF-SIMS and a C60 probe [J].
Cheng, J ;
Winograd, N .
ANALYTICAL CHEMISTRY, 2005, 77 (11) :3651-3659
[5]   Is proton cationization promoted by polyatomic primary ion bombardment during time-of-flight secondary ion mass spectrometry analysis of frozen aqueous solutions? [J].
Conlan, XA ;
Lockyer, NP ;
Vickerman, JC .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (08) :1327-1334
[6]   Development and experimental application of a gold liquid metal ion source [J].
Davies, N ;
Weibel, DE ;
Blenkinsopp, P ;
Lockyer, N ;
Hill, R ;
Vickerman, JC .
APPLIED SURFACE SCIENCE, 2003, 203 :223-227
[7]   TOF-SIMS 3D biomolecular imaging of Xenopus laevis oocytes using buckminsterfullerene (C60) primary ions [J].
Fletcher, John S. ;
Lockyer, Nicholas P. ;
Vaidyanathan, Seetharaman ;
Vickerman, John C. .
ANALYTICAL CHEMISTRY, 2007, 79 (06) :2199-2206
[8]   TOF-SIMS analysis using C60- effect of impact energy on yield and damage [J].
Fletcher, JS ;
Conlan, XA ;
Jones, EA ;
Biddulph, G ;
Lockyer, NP ;
Vickerman, JC .
ANALYTICAL CHEMISTRY, 2006, 78 (06) :1827-1831
[9]  
Gillen G, 1998, RAPID COMMUN MASS SP, V12, P1303, DOI 10.1002/(SICI)1097-0231(19981015)12:19<1303::AID-RCM330>3.0.CO
[10]  
2-7