Accuracy of eosinophils and eosinophil cationic protein to predict steroid improvement in asthma

被引:81
作者
Meijer, RJ
Postma, DS
Kauffman, HF
Arends, LR
Koëter, GH
Kerstjens, HAM
机构
[1] Univ Groningen Hosp, Dept Pulm Dis, NL-9700 RB Groningen, Netherlands
[2] Univ Groningen Hosp, Dept Allergol, Groningen, Netherlands
[3] Erasmus Univ, Dept Epidemiol & Biostat, NL-3000 DR Rotterdam, Netherlands
关键词
asthma; clinical response; corticosteroids; ECP; eosinophils; inflammation; nitric oxide; quality of life;
D O I
10.1046/j.1365-2222.2002.01412.x
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
Background There is a large variability in clinical response to corticosteroid treatment in patients with asthma. Several markers of inflammation like eosinophils and eosinophil cationic protein (ECP), as well as exhaled nitric oxide (NO), are good candidates to predict clinical response. Aim We wanted to determine whether we could actually predict a favourable response to inhaled corticosteroids in individual patients. Methods One hundred and twenty patients with unstable asthma were treated with either prednisolone 30 mg/day, fluticasone propionate 1000 mug/day b.i.d. or fluticasone propionate 250 mug/day b.i.d., both via Diskhaler. They were treated during 2 weeks, in a double-blind, parallel group, double dummy design. We measured eosinophils and ECP in blood and sputum, and exhaled nitric oxide as inflammatory parameters before and after 2 weeks in order to predict the changes in forced expiratory volume in 1 s (FEV1), provocative concentration of methacholine causing a 20% fall in FEV1 (PC20 Mch), and asthma quality of life (QOL). Secondly, to test whether these results were applicable in clinical practice we determined the individual prediction of corticosteroid response. Results We fond that changes in FEV1, PC20 Mch and QOL with corticosteroids were predominantly predicted by their respective baseline value and to a smaller extent by eosinophils in blood or sputum. ECP, measured in blood or sputum, was certainly not better than eosinophils in predicting clinical response to corticosteroids. Smoking status was an additional predictor for change in FEV1, but not for change in PC20 Mch or QOL. Prediction of a good clinical response was poor. For instance, high sputum eosinophils (greater than or equal to 3%) correctly predicted an improvement in PC20 Mch in only 65% of the patients. Conclusion Our findings show that baseline values of the clinical parameters used as outcome parameters are the major predictors of clinical response to corticosteroids. Eosinophil percentage in blood or sputum adds to this, whereas ECP provides no additional information. Correct prediction of clinical response in an individual patient, however, remains poor with our currently used clinical and inflammatory parameters.
引用
收藏
页码:1096 / 1103
页数:8
相关论文
共 44 条
[1]  
ALVING K, 1993, EUR RESPIR J, V6, P1368
[2]  
[Anonymous], 1987, AM REV RESPIR DIS, V136, P225
[3]  
[Anonymous], 2013, Clinical trials: a practical approach
[4]   NITRIC-OXIDE AND ASTHMATIC INFLAMMATION [J].
BARNES, PJ ;
LIEW, FY .
IMMUNOLOGY TODAY, 1995, 16 (03) :128-130
[5]   A comparison of exhaled nitric oxide and induced sputum as markers of airway inflammation [J].
Berlyne, GS ;
Parameswaran, K ;
Kamada, D ;
Efthimiadis, A ;
Hargreave, FE .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2000, 106 (04) :638-644
[6]  
BEUTLER E, 1995, WILLIAMS HEMATOLGY
[7]  
BROWN HM, 1958, LANCET, V2, P1245
[8]   GLUCOCORTICOID RESISTANCE IN CHRONIC ASTHMA - GLUCOCORTICOID PHARMACOKINETICS, GLUCOCORTICOID RECEPTOR CHARACTERISTICS, AND INHIBITION OF PERIPHERAL-BLOOD T-CELL PROLIFERATION BY GLUCOCORTICOIDS INVITRO [J].
CORRIGAN, CJ ;
BROWN, PH ;
BARNES, NC ;
SZEFLER, SJ ;
TSAI, JJ ;
FREW, AJ ;
KAY, AB .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1991, 144 (05) :1016-1025
[9]   Dissociation between airway inflammation and airway hyperresponsiveness in allergic asthma [J].
Crimi, E ;
Spanevello, A ;
Neri, M ;
Ind, PW ;
Rossi, GA ;
Brusasco, V .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1998, 157 (01) :4-9
[10]   Effects of budesonide and fluticasone on 24-hour plasma cortisol - A dose-response [J].
Donnelly, R ;
Williams, KM ;
Baker, AB ;
Badcock, CA ;
Day, RO ;
Seale, JP .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1997, 156 (06) :1746-1751