Pediatric circulatory support: An FDA perspective

被引:9
作者
Rinaldi, JE [1 ]
Chen, EA [1 ]
Berman, MR [1 ]
机构
[1] US FDA, Ctr Devices & Radiol Hlth, Rockville, MD 20852 USA
关键词
D O I
10.1097/01.mat.0000181508.26853.dc
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The Department of Health and Human Services, at the direction of Congress, has recently begun to address concerns regarding the development of medical devices designed specifically for the pediatric population, including devices for pediatric mechanical circulatory support, as evidenced by the National Institutes of Health's (NIH) funding of several development contracts. Food and Drug Administration (FDA) approval for marketing of these devices will typically follow either of two regulatory pathways: the Humanitarian Device Exemption (HDE) or the Premarket Application (PMA). An HIDE is limited both in the extent of clinical use and economic benefit to the manufacturer, but does not require data derived from a clinical trial for market approval. A PMA allows for use in a larger patient population and offers economic benefit for the manufacturer; it does, however, almost always necessitate data derived from a clinical trial. The HDE and PMA require demonstration of a reasonable assurance of safety. in addition, an HDE requires a demonstration of probable benefit, whereas a PMA requires a demonstration of a reasonable assurance of effectiveness. The evidence that can be used to support an HDE or a PMA approval may include both preclinical and clinical data. Types of preclinical tests needed depend upon the device design and its intended use, because circulatory support devices are all unique.
引用
收藏
页码:533 / 535
页数:3
相关论文
共 5 条
[1]   Mechanical circulatory support for infants and children with cardiac disease [J].
Duncan, BW .
ANNALS OF THORACIC SURGERY, 2002, 73 (05) :1670-1677
[2]   Circulatory support with pneumatic paracorporeal ventricular assist device in infants and children [J].
Hetzer, R ;
Loebe, M ;
Potapov, EV ;
Weng, YG ;
Stiller, B ;
Hennig, E ;
Alexi-Meskishvili, V ;
Lange, PE .
ANNALS OF THORACIC SURGERY, 1998, 66 (05) :1498-1505
[3]   International society for heart and lung transplantation: Practice guidelines for management of heart failure in children [J].
Rosenthal, D ;
Chrisant, MRK ;
Edens, E ;
Mahony, L ;
Canter, C ;
Colan, S ;
Dubin, A ;
Lamour, J ;
Ross, R ;
Shaddy, R ;
Addonizio, L ;
Beerman, L ;
Berger, S ;
Bernstein, D ;
Blume, E ;
Boucek, M ;
Checchia, P ;
Dipchand, A ;
Drummond-Webb, J ;
Fricker, J ;
Friedman, R ;
Hallowell, S ;
Jaquiss, R ;
Mital, S ;
Pahl, E ;
Pearce, B ;
Rhodes, L ;
Rotondo, K ;
Rusconi, P ;
Scheel, J ;
Singh, TP ;
Towbin, J .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2004, 23 (12) :1313-1333
[4]   Pneumatic pulsatile ventricular assist devices in children under 1 year of age [J].
Stiller, B ;
Weng, YG ;
Hübler, M ;
Lemmer, J ;
Nagdyman, N ;
Redlin, M ;
Lange, PE ;
Hetzer, R .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2005, 28 (02) :234-239
[5]  
*US DEP HHS, 2004, GUID IND FDA STAFF P