Acousto-optical deflection-based laser beam scanning for fluorescence detection on multichannel electrophoretic microchips

被引:62
作者
Huang, Z
Munro, N
Huhmer, AFR
Landers, JP
机构
[1] Univ Virginia, Dept Chem, Charlottesville, VA 22904 USA
[2] Univ Pittsburgh, Dept Chem, Pittsburgh, PA 15260 USA
关键词
D O I
10.1021/ac990740u
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Laser beam scanning driven by an acousto-optical deflector (AOD) is presented for multimicrochannel laser-induced fluorescence (LIF) detection during microchip-based electrophoresis. While fast laser beam scanning for LIF detection on capillary or microchannel arrays can been achieved with galvanometric scanning or a translating stage, it can also be accomplished by using acoustic waves to deflect the laser beam in a manner that is dependent on the acoustic frequency. AOD scanning differs from other approaches in that no moving parts are required, and the scan frequency is faster than conventional approaches. Using a digital/analog (D/A)converter to provide addressing voltages to a voltage/frequency converter, rapidly changing the frequency input to the AOD allows the laser beam to be addressed accurately on a microchip. With the ability to change the frequency on the nanosecond time scale, scanning rates as high as 30 Hz for Windows-based LabView programming are possible, with much faster scan rates achievable if a microprocessor-embedded system is utilized. In addition to spatial control, temporal control is easily attainable via raster scanning or random addressing, allowing for the scanning process to be self-aligning. Since the D/A output voltages drive the scanning of the laser beam over all channels, the software can define addressing voltages corresponding to the microchannel centers and, subsequently, fluorescence data can be collected from only those locations. This method allows for flexible, highspeed, self-align scanning for fluorescence detection in capillary or microchip electrophoresis and has the potential to be applied to a number of applications.
引用
收藏
页码:5309 / 5314
页数:6
相关论文
共 25 条
[1]  
BASS M, 1995, HDB OPTICS, V2, pCH19
[2]   High-speed, random-access fluorescence microscopy .1. High-resolution optical recording with voltage-sensitive dyes and ion indicators [J].
Bullen, A ;
Patel, SS ;
Saggau, P .
BIOPHYSICAL JOURNAL, 1997, 73 (01) :477-491
[3]   DNA sequencing - Massively parallel genomics [J].
Fodor, SPA .
SCIENCE, 1997, 277 (5324) :393-&
[4]   HIGHLY SENSITIVE OPTICAL MEASUREMENT TECHNIQUES BASED ON ACOUSTOOPTIC DEVICES [J].
GASS, PA ;
SCHALK, S ;
SAMBLES, JR .
APPLIED OPTICS, 1994, 33 (31) :7501-7510
[5]   CAPILLARY ELECTROPHORESIS [J].
GORDON, MJ ;
HUANG, XH ;
PENTONEY, SL ;
ZARE, RN .
SCIENCE, 1988, 242 (4876) :224-228
[6]   Microchip device for performing enzyme assays [J].
Hadd, AG ;
Raymond, DE ;
Halliwell, JW ;
Jacobson, SC ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 1997, 69 (17) :3407-3412
[7]   MICROMACHINING A MINIATURIZED CAPILLARY ELECTROPHORESIS-BASED CHEMICAL-ANALYSIS SYSTEM ON A CHIP [J].
HARRISON, DJ ;
FLURI, K ;
SEILER, K ;
FAN, ZH ;
EFFENHAUSER, CS ;
MANZ, A .
SCIENCE, 1993, 261 (5123) :895-897
[8]   HIGH-PERFORMANCE ELECTROPHORESIS - ELIMINATION OF ELECTROENDOSMOSIS AND SOLUTE ADSORPTION [J].
HJERTEN, S .
JOURNAL OF CHROMATOGRAPHY, 1985, 347 (02) :191-198
[9]  
HOFGAERTNER W, 1999, IN PRESS CLIN CHEM
[10]   DNA SEQUENCING USING CAPILLARY ARRAY ELECTROPHORESIS [J].
HUANG, XHC ;
QUESADA, MA ;
MATHIES, RA .
ANALYTICAL CHEMISTRY, 1992, 64 (18) :2149-2154