Column selectivity in reversed-phase liquid chromatography I. A general quantitative relationship

被引:208
作者
Wilson, NS
Nelson, MD
Dolan, JW
Snyder, LR
Wolcott, RG
Carr, PW
机构
[1] LC Resources, Walnut Creek, CA 94596 USA
[2] Linfield Coll, Dept Chem, McMinnville, OR 97128 USA
[3] Univ Minnesota, Dept Chem, Minneapolis, MN 55455 USA
基金
美国国家卫生研究院;
关键词
column selectivity; alkyl-silica columns; retention prediction; selectivity; stationary phases; LC;
D O I
10.1016/S0021-9673(02)00659-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Retention factors k have been measured for 67 neutral, acidic and basic solutes of highly diverse molecular structure (size, shape, polarity, hydrogen bonding, pK(a), etc.) on 10 different C-18 columns (other conditions constant). These data have been combined with k values from a previous study (86 solutes, five different C-8 and C-18 columns) to develop a six-term equation for the correlation of retention as a function of solute and column. Values of k can be correlated with an accuracy of +/-1-2% (1 standard deviation). This suggests that all significant contributions to column selectivity have been identified (and can be measured) for individual alkyl-silica columns which do not have an embedded polar group. That is, columns of the latter kind can be quantitatively characterized in terms of selectivity for use in the separation of any sample. (C) 2002 Published by Elsevier Science B.V.
引用
收藏
页码:171 / 193
页数:23
相关论文
共 32 条
[1]  
Abraham MH, 1997, J PHYS ORG CHEM, V10, P358, DOI 10.1002/(SICI)1099-1395(199705)10:5<358::AID-POC907>3.0.CO
[2]  
2-N
[3]  
ABRAHAM MH, 1993, CHEM SOC REV, V23, P660
[4]   Test analytes for studies of the molecular mechanism of chromatographic separations by quantitative structure-retention relationships [J].
Al-Haj, MA ;
Kaliszan, R ;
Nasal, A .
ANALYTICAL CHEMISTRY, 1999, 71 (15) :2976-2985
[5]   Quantitative structure-retention relationships with model analytes as a means of an objective evaluation of chromatographic columns [J].
Al-Haj, MA ;
Kaliszan, R ;
Buszewski, B .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2001, 39 (01) :29-38
[6]  
Blackwell JA, 1998, HRC-J HIGH RES CHROM, V21, P427
[7]   Influence of solvent effects on retention for a porous polymer sorbent in reversed phase liquid chromatography [J].
Bolliet, D ;
Poole, CF .
CHROMATOGRAPHIA, 1997, 46 (7-8) :381-398
[8]   Conjoint prediction of the retention of neutral and ionic compounds (phenols) in reversed-phase liquid chromatography using the solvation parameter model [J].
Bolliet, D ;
Poole, CF ;
Rosés, M .
ANALYTICA CHIMICA ACTA, 1998, 368 (1-2) :129-140
[9]   STUDY OF TEMPERATURE AND MOBILE-PHASE EFFECTS IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY BY THE USE OF THE SOLVATOCHROMIC COMPARISON METHOD [J].
CARR, PW ;
DOHERTY, RM ;
KAMLET, MJ ;
TAFT, RW ;
MELANDER, W ;
HORVATH, C .
ANALYTICAL CHEMISTRY, 1986, 58 (13) :2674-2680
[10]   Selectivity differences for C18 and C8 reversed-phase columns as a function of temperature and gradient steepness I.: Optimizing selectivity and resolution [J].
Dolan, JW ;
Snyder, LR ;
Blanc, T ;
Van Heukelem, L .
JOURNAL OF CHROMATOGRAPHY A, 2000, 897 (1-2) :37-50