Comparison between 20G and 22G needle for second trimester amniocentesis in terms of technical aspects and short-term complications

被引:15
作者
Athanasiadis, Apostolos P. [1 ,2 ]
Pantazis, Konstantinos [1 ]
Goulis, Dimitrios G. [1 ]
Chatzigeorgiou, Konstantinos [1 ]
Vaitsi, Violeta [3 ]
Assimakopoulos, Efstratios [1 ]
Tzevelekis, Filippos [1 ]
Tsalikis, Tryfon [1 ]
Bontis, John N. [1 ]
机构
[1] Aristotle Univ Thessaloniki, Dept Obstet & Gynecol 1, Papageorgiou Gen Hosp, Thessaloniki 54603, Greece
[2] Prenatal Diagnost Ctr Thessaloniki, Thessaloniki, Greece
[3] Aristotle Univ Thessaloniki, Hippokrat Gen Hosp, Dept Obstet & Gynecol 2, Thessaloniki 54603, Greece
关键词
amniocentesis; amniocentesis needle; amniocentesis complications; TRIAL; RISK;
D O I
10.1002/pd.2283
中图分类号
Q3 [遗传学];
学科分类号
071007 ; 090102 ;
摘要
Objective To compare short-term complications of amniocentesis using 20G versus 22G needle. Methods A total of 200 women referred for mid-trimester amniocentesis were randomized to a 20G (Group 1, n = 100) or 22G amniocentesis needle (Group 11, n = 100). The primary outcome was intrauterine bleeding at needle insertion. The operator reported technical aspects and patient's reactions immediately after the procedure. Women's perception of discomfort 30 min after the procedure and complications after 2 weeks were recorded. Results Intrauterine bleeding at needle insertion was similar between groups (4/100 vs 8/100). When only transplacental taps were analyzed, bleeding was significantly lower in Group 1 (4/20 vs 8/14, p = 0.035). Fluid retrieval was faster in Group 1 (9.6 vs 26.8 sec, p < 0.001). In all, 65% of women in Group I versus 30% in Group 11 reported discomfort during the procedure, although discomfort 30 min after the procedure and complications within 2 weeks after the procedure were similar in the two groups. Conclusion Amniocentesis with 20G needle is associated with lower risk of intrauterine bleeding in case of transplacental needle insertion and allows for faster fluid retrieval, as compared with 22G needle. Nevertheless, 20G needle is associated with more immediate discomfort during the procedure. Copyright (C) 2009 John Wiley & Sons, Ltd.
引用
收藏
页码:761 / 765
页数:5
相关论文
共 7 条
[1]   Factors influencing the flow rate through a surgical defect in human fetal membranes [J].
Devlieger, R ;
Gratacos, E ;
Ardon, H ;
Deprest, J .
PRENATAL DIAGNOSIS, 2002, 22 (03) :201-205
[2]  
ROMERO R, 1991, PRINCIPLES PRACTICE
[3]  
Scott F, 2002, AUST NZ J OBSTET GYN, V42, P55
[4]  
STEELE MW, 1966, LANCET, V1, P383
[5]  
TABOR A, 1988, LANCET, V1, P183
[6]  
TABOR A, 1986, LANCET, V1, P1287
[7]   Does local anesthesia at mid-trimester amniocentesis decrease pain experience? A randomized trial in 220 patients [J].
Van Schoubroeck, D ;
Verhaeghe, J .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2000, 16 (06) :536-538