Cue-based segmentation of 4D cardiac image sequences

被引:6
作者
Reinhardt, JM
Wang, AJ
Weldon, TP
Higgins, WE
机构
[1] Univ Iowa, Dept Biomed Engn, Iowa City, IA 52242 USA
[2] GTE Informat Technol, Irving, TX 75038 USA
[3] Univ N Carolina, Dept Elect Engn, Charlotte, NC 28223 USA
[4] Penn State Univ, Dept Elect Engn, University Pk, PA 16802 USA
[5] Penn State Univ, Dept Comp Sci & Engn, University Pk, PA 16802 USA
[6] Penn State Univ, Dept Bioengn, University Pk, PA 16802 USA
基金
美国国家卫生研究院;
关键词
image segmentation; cue-based image analysis; multidimensional image processing; medical imaging; 3D imaging; cardiac imaging; interpolation; 4D image processing;
D O I
10.1006/cviu.1999.0818
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Medical imaging scanners now exist that can generate 4D cardiac images, Since the heart moves, cardiac anatomy and physiology can be studied using 4D image sequences. Interactive manual 4D image analysis Can be time-consuming and error prone-automatic and semi-automatic methods have many advantages over manual segmentation. This paper describes a procedure for performing semi-automatic image segmentation on 4D image sequences, Our procedure is based on a small set of user defined image-segmentation cues specified at certain time points in the sequence. These cues are then automatically interpolated or extrapolated for the remaining time points, The complete set of cues is interpreted and used to generate a sequence of image processing operations (such as operators for image enhancement, morphological processing, and region segmentation) that can subsequently segment the 4D image, This procedure permits 4D cardiac image segmentation with only a small amount of user interaction. The proposed approach compares favorably to results generated by defining cues on each individual volume and to results generated completely manually. The 4D approach also requires significantly less interaction time than pure manual analysis. (C) 2000 Academic Press.
引用
收藏
页码:251 / 262
页数:12
相关论文
共 17 条
[1]  
AMINI AA, 1998, LECT NOTES COMPUTER, V1496
[2]   CARDIAC COMPUTED-TOMOGRAPHY [J].
BOYD, DP ;
LIPTON, MJ .
PROCEEDINGS OF THE IEEE, 1983, 71 (03) :298-307
[3]   A MODEL-BASED 4-DIMENSIONAL LEFT-VENTRICULAR SURFACE DETECTOR [J].
FABER, TL ;
STOKELY, EM ;
PESHOCK, RM ;
CORBETT, JR .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (03) :321-329
[4]   Relaxation methods for supervised image segmentation [J].
Hansen, MW ;
Higgins, WE .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1997, 19 (09) :949-962
[5]   SHAPE-BASED INTERPOLATION OF TREE-LIKE STRUCTURES IN 3-DIMENSIONAL IMAGES [J].
HIGGINS, WE ;
MORICE, C ;
RITMAN, EL .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (03) :439-450
[6]   INTERACTIVE MORPHOLOGICAL WATERSHED ANALYSIS FOR 3D MEDICAL IMAGES [J].
HIGGINS, WE ;
OJARD, EJ .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1993, 17 (4-5) :387-395
[7]  
HIGGINS WE, 1991, IEEE T MED IMAGING, V10, P228
[8]  
HIGGINS WE, 1993, 15 ANN INT C IEEE EN, P136
[9]  
HOFFMAN EA, 1992, SPIE P BIOMED IMAGE, V1660, P1
[10]   SHAPE-BASED INTERPOLATION OF MULTIDIMENSIONAL OBJECTS [J].
RAYA, SP ;
UDUPA, JK .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1990, 9 (01) :32-42