State-of-the-art of the hyphenation of capillary electrochromatography with mass spectrometry

被引:50
作者
Barceló-Barrachina, E [1 ]
Moyano, E [1 ]
Galceran, MT [1 ]
机构
[1] Univ Barcelona, Dept Analyt Chem, E-08028 Barcelona, Spain
关键词
capillary electrochromatography; mass spectrometry; review;
D O I
10.1002/elps.200305908
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The high separation efficiency and loading capacity of capillary electrochromatography (CEC) make it an attractive separation mode for coupling with mass spectrometry (MS), which has the ability to unambiguously identify analytes with high selectivity and sensitivity. We present an overview of recent advances on both instrumentation and separation columns employed in CEC-MS systems. In particular, the main characteristics of the stationary phases, as well as the configurations of the column outlet that are related with the coupling arrangements of the MS ionization sources, are reported. At present, packed columns and conventional electrospray ionization (ESI) sources are mainly employed in CEC-MS. Nevertheless, the use of monolithic capillary columns and nanoelectrospray sources has the potential for wide acceptance in the next future. Moreover, the main features of several mass analyzers including ion trap, quadrupole, time-of-flight, magnetic sector, and Fourier transform-ion cyclotron resonance are examined. Finally, current applications of this technology, mainly in the pharmaceutical field and proteomics, are reviewed.
引用
收藏
页码:1927 / 1948
页数:22
相关论文
共 86 条
[1]  
AJRVIS SA, 1998, ADV MASS SPECTROM
[2]   Recent advances in capillary electrophoresis electrospray mass spectrometry [J].
Banks, JF .
ELECTROPHORESIS, 1997, 18 (12-13) :2255-2266
[3]   Microfluidic devises connected to fused-silica capillaries with minimal dead volume [J].
Bings, NH ;
Wang, C ;
Skinner, CD ;
Colyer, CL ;
Thibault, P ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 1999, 71 (15) :3292-3296
[4]   Control of dispersion in capillary electrochromatography coupled to UV and mass spectrometric detection [J].
Boughtflower, RJ ;
Paterson, CJ ;
Knox, JH .
JOURNAL OF CHROMATOGRAPHY A, 2000, 887 (1-2) :409-420
[5]  
Bruin GJM, 2000, ELECTROPHORESIS, V21, P3931, DOI 10.1002/1522-2683(200012)21:18<3931::AID-ELPS3931>3.0.CO
[6]  
2-M
[7]  
Cahours X, 2002, ELECTROPHORESIS, V23, P2320, DOI 10.1002/1522-2683(200207)23:14<2320::AID-ELPS2320>3.0.CO
[8]  
2-P
[9]   Capillary electrochromatographic separation of metal ion species with on-line detection by inductively coupled plasma mass spectrometry [J].
Chen, WH ;
Lin, SY ;
Liu, CY .
ANALYTICA CHIMICA ACTA, 2000, 410 (1-2) :25-35
[10]   Analysis of selected withanolides in plant extract by capillary electrochromatography and microemulsion electrokinetic chromatography [J].
Cherkaoui, S ;
Cahours, X ;
Veuthey, JL .
ELECTROPHORESIS, 2003, 24 (03) :336-342