Multienzyme electrochemical sensor array for determination of heavy metal ions

被引:52
作者
Kukla, AL
Kanjuk, NI
Starodub, NF
Shirshov, YM
机构
[1] Inst Semicond Phys, UA-252650 Kiev 28, Ukraine
[2] AV Palladin Biochem Inst, UA-252030 Kiev 30, Ukraine
来源
SENSORS AND ACTUATORS B-CHEMICAL | 1999年 / 57卷 / 1-3期
关键词
biosensors; multienzymatic electrochemical sensors; heavy metal ions;
D O I
10.1016/S0925-4005(99)00153-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A multienzyme electrochemical sensor array is developed. It is based on capacitance pH-sensitive electrolyte-insulator-semiconductor (EIS) sensors with silicon nitride ion-sensitive layers and different forms of cholinesterase, urease and glucose oxidase as sensitive elements. With this sensor array, we used a multienzyme analysis to recognize the heavy metal ions in solutions containing a mixture of different metal ions, as well as for determination of their content in the analysed samples. The content of toxic elements was determined by estimation of the residual activity of enzymatic membranes after the injection of analysed samples. The conditions for enzyme sensors operation, such as buffer capacity, substrate concentration, time of incubation and time of response signal measurement, were optimised to reach the maximal sensitivity of multisensor for analysis of heavy metal ions in the investigated solutions. It was shown that multienzyme analysis followed by mathematical processing is an efficient approach to develop sensor arrays for toxic substrates detection. (C) 1999 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:213 / 218
页数:6
相关论文
共 14 条
[1]   ANTICHOLINESTERASE ACTIVITY MEASUREMENT BY A CHOLINE BIOSENSOR - APPLICATION IN WATER ANALYSIS [J].
BERNABEI, M ;
CHIAVARINI, S ;
CREMISINI, C ;
PALLESCHI, G .
BIOSENSORS & BIOELECTRONICS, 1993, 8 (05) :265-271
[2]   Organophosphorus pesticide (Paraoxon) analysis using solid state sensors [J].
Campanella, L ;
Colapicchioni, C ;
Favero, G ;
Sammartino, MP ;
Tomassetti, M .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 33 (1-3) :25-33
[3]  
Compagnone D, 1995, P SOC PHOTO-OPT INS, V2504, P141, DOI 10.1117/12.224096
[4]   Continuous-flow system for on line water monitoring using back side contact ISFET-based sensors [J].
Jimenez, C ;
Marques, I ;
Bartroli, J .
ANALYTICAL CHEMISTRY, 1996, 68 (21) :3801-3807
[5]   Computer simulation of transport processes in biosensor microreactors [J].
Kukla, AL ;
Shirshov, YM .
SENSORS AND ACTUATORS B-CHEMICAL, 1998, 48 (1-3) :461-466
[6]   APPLICATION OF ENZYME FIELD-EFFECT TRANSISTOR SENSOR ARRAYS AS DETECTORS IN A FLOW-INJECTION SYSTEM FOR SIMULTANEOUS MONITORING OF MEDIUM COMPONENTS .1. PREPARATION AND CALIBRATION [J].
KULLICK, T ;
BEYER, M ;
HENNING, J ;
LERCH, T ;
QUACK, R ;
ZEITZ, A ;
HITZMANN, B ;
SCHEPER, T ;
SCHUGERL, K .
ANALYTICA CHIMICA ACTA, 1994, 296 (03) :263-269
[7]   Disposable cuvette test with integrated sensor layer for enzymatic determination of heavy metals [J].
Preininger, C ;
Wolfbeis, OS .
BIOSENSORS & BIOELECTRONICS, 1996, 11 (10) :981-990
[8]  
SCHONING MJ, 1997, P EUROSENSORS 11, V2, P871
[9]  
SHIRSHOV YM, 1997, P EUROSENSORS 11, V2, P727
[10]  
Starodub N., 1998, BIOSENSORS DIRECT MO, P209