Feasibility study of multileaf collimated electrons with a scattering foil based accelerator

被引:33
作者
Klein, EE
Li, ZF
Low, DA
机构
[1] Mallinckrodt Institute of Radiology, Radiation Oncology Center, St. Louis, MO 63110
关键词
electron; MLC; multileaf collimation; electron arc;
D O I
10.1016/S0167-8140(96)01822-1
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: There is an ever evolving process to improve the technical aspects of electron beam delivery. Both the foil/applicator and scanning electron beam systems have gone through recent upheavals. Concomitantly, multileaf collimators are now a staple method for collimating photons. We undertook a study of multileaf collimated electron beam (MLCEB) using a dual scattering foil system. Materials and methods: We compared MLCEB with applicator collimated electron beams (AEB) by examining the dosimetric aspects of the two systems using 70 and 80 cm SSDs for the MLCEB, the minimum practical SSDs achievable. Percent depth dose, isodose profiles, output factors, leakage, surface dose, bremstrahlung, effective SSDs, etc. were measured using film and/or ion chamber. Clinical fields, such as posterior neck node (PNN), were compared. We also investigated the use of MLCEB for are therapy using segments. Results: In all cases, the MLCEB performed inferior, as judged by isodoses, uniformity index (UI) and penumbra analysis. The 80 cm SSD (minimum for PNN), low energy, small fields, was the worst case. For a 6 MeV beam, the UI/penumbra was 0.823/10 mm for the AEB, and 0.561/29 mm for the MLCEB at 80 cm SSD. The PNN multileaf fields exhibited narrow 90% and 80% isodose lines, and wide 20% and 10% lines. Conclusions: We conclude that multileaf for PNN fields could not be matched to adjacent off-cord photon fields. The 'stair-stepping' effect associated with MLC photons was absent for electrons.
引用
收藏
页码:189 / 196
页数:8
相关论文
共 16 条
[1]   CHARACTERISTIC PARAMETERS OF 6-21 MEV ELECTRON-BEAMS FROM A 21-MEV LINEAR-ACCELERATOR [J].
ALGHAZI, MSAL ;
LINGMAN, D ;
ARJUNE, B ;
GILBERT, LD ;
THEKKUMTHALA, J .
MEDICAL PHYSICS, 1991, 18 (04) :821-828
[2]  
[Anonymous], 1984, 35 ICRU
[3]  
BJARNGARD B E, 1976, Medical Physics (Woodbury), V3, P153, DOI 10.1118/1.594281
[4]   DESIGN PRINCIPLES AND CLINICAL POSSIBILITIES WITH A NEW GENERATION OF RADIATION-THERAPY EQUIPMENT - A REVIEW [J].
BRAHME, A .
ACTA ONCOLOGICA, 1987, 26 (06) :403-412
[5]   ELECTRON-BEAM DOSE CALCULATIONS [J].
HOGSTROM, KR ;
MILLS, MD ;
ALMOND, PR .
PHYSICS IN MEDICINE AND BIOLOGY, 1981, 26 (03) :445-459
[6]   MATCHING OF ELECTRON AND PHOTON BEAMS WITH A MULTI-LEAF COLLIMATOR [J].
KARLSSON, M ;
ZACKRISSON, B .
RADIOTHERAPY AND ONCOLOGY, 1993, 29 (03) :317-326
[7]   RADIATION LEAKAGE FROM LINAC ELECTRON APPLICATOR ASSEMBLY [J].
KEYS, RA ;
PURDY, JA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1984, 10 (05) :713-721
[8]   Clinical implementation of a commercial multileaf collimator: Dosimetry, networking, simulation, and quality assurance [J].
Klein, EE ;
Harms, WB ;
Low, DA ;
Willcut, V ;
Purdy, JA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1195-1208
[9]   Changes in electron beam dosimetry with a new scattering foil-applicator system on a CL2100C [J].
Klein, E.E. ;
Low, D.A. ;
Purdy, J.A. .
International Journal of Radiation Oncology, Biology, Physics, 1995, 32 (02)
[10]   COLLIMATION OF HIGH-ENERGY ELECTRON-BEAMS [J].
LAX, I ;
BRAHME, A .
ACTA RADIOLOGICA ONCOLOGY, 1980, 19 (03) :199-207