Determination of phosphate in natural waters by capillary electrophoresis - Influence of solution composition on migration time and response

被引:16
作者
vandenHoop, MAGT
vanStaden, JJ
机构
关键词
water analysis; environmental analysis; buffer composition; phosphate; inorganic anions;
D O I
10.1016/S0021-9673(96)01000-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper deals with the determination of the more complex phosphate anion by capillary electrophoresis using indirect UV detection. First, the pH of the running electrolyte influences both the migration time and the response of the phosphate anion. Both effects could be explained well by taking into account phosphorus speciation in solution. In addition, the experimental method has been applied to three different sets of natural water systems; (i) groundwater, (ii) surface water and (iii) stemflow samples. The migration time behaviour of phosphate was different for the three sample sets and, hence, difficulties arise with respect to a clear and unique identification of the compound. Deviations herein could be minimized by applying a correction method for migration time drift. Concentrations of phosphate could be quantified in most samples and were confirmed by a colorimetric method. Average recoveries of additions of phosphate to groundwater, surface water and stemflow samples were 105, 83 and 103%, respectively. For one stemflow sample, quantitative recovery of phosphate was possible only by changing the pH of the running electrolyte solution. The latter observation might be very useful in setting up speciation-related measurement methods.
引用
收藏
页码:321 / 328
页数:8
相关论文
共 18 条
[1]  
BEEK J, 1988, SOIL CHEM B, P259
[2]   DEPENDENCE OF THE ELECTROOSMOTIC MOBILITY ON THE APPLIED ELECTRIC-FIELD AND ITS REPRODUCIBILITY IN CAPILLARY ELECTROPHORESIS [J].
BELLO, MS ;
CAPELLI, L ;
RIGHETTI, PG .
JOURNAL OF CHROMATOGRAPHY A, 1994, 684 (02) :311-322
[3]  
Bodek I., 1988, Environmental inorganic chemistry
[4]   NEW APPROACH TO THE ANALYSIS OF LOW-LEVELS OF ANIONS IN WATER [J].
BONDOUX, G ;
JANDIK, P ;
JONES, WR .
JOURNAL OF CHROMATOGRAPHY, 1992, 602 (1-2) :79-88
[5]   OPTIMIZATION OF INDIRECT UV DETECTION IN CAPILLARY ZONE ELECTROPHORESIS OF LOW-MOLECULAR-MASS ANIONS [J].
BUCHBERGER, W ;
COUSINS, SM ;
HADDAD, PR .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1994, 13 (08) :313-319
[6]  
*DION BV, 1992, 68 DION BV
[7]   Comparison of different electroosmotic flow modifiers in the analysis of inorganic anions by capillary electrophoresis [J].
Galceran, MT ;
Puignou, L ;
Diez, M .
JOURNAL OF CHROMATOGRAPHY A, 1996, 732 (01) :167-174
[8]  
Greenberg A.G., 1985, STANDARD METHODS EXA
[9]   Optimization of the response of phosphate separated by capillary zone electrophoresis [J].
Harakuwe, AH ;
Haddad, PR .
ANALYTICAL COMMUNICATIONS, 1996, 33 (03) :103-105
[10]   BIAS IN QUANTITATIVE CAPILLARY ZONE ELECTROPHORESIS CAUSED BY ELECTROKINETIC SAMPLE INJECTION [J].
HUANG, XH ;
GORDON, MJ ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1988, 60 (04) :375-377