Carbonate interferences by ion chromatographic determination of anions in mineral waters

被引:15
作者
Novic, M [1 ]
Lecnik, B [1 ]
Hudnik, V [1 ]
Pihlar, B [1 ]
机构
[1] UNIV LJUBLJANA,FAC CHEM & CHEM TECHNOL,LJUBLJANA,SLOVENIA
关键词
mineral water; water analysis; carbonate;
D O I
10.1016/S0021-9673(96)00905-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The high content of hydrogen carbonate anions and dissolved CO2 in some mineral waters interfere with the determination of anions in such samples by ion chromatography. It was found that the irreproducibility of retention times of all anions present in the samples was caused by on-column neutralisation of CO32- to HCO3- by CO2. Microbubbles of CO2 released downstream by the suppressor inhibited exchange of Na+ with H3O+ resulting in lower conductivity and consequently in the decrease of chloride peak. To avoid peak deformation and overlapping caused by carbonate species, they should be removed by acidification followed by CO2 elimination in a gas separation unit. To prevent sample contamination by the anion of the added acid, the electrodialytic clean-up procedure was applied. The liberated CO2 was removed in a microporous Gore-Tex semipermeable tubing connected in series with the dialytic cell. The developed dialytic clean-up procedure was applied to the analysis of some typical mineral waters.
引用
收藏
页码:249 / 256
页数:8
相关论文
共 14 条
[1]   DONNAN DIALYSIS MATRIX NORMALIZATION FOR THE VOLTAMMETRIC DETERMINATION OF METAL-IONS [J].
COX, JA ;
TWARDOWSKI, Z .
ANALYTICA CHIMICA ACTA, 1980, 119 (01) :39-45
[2]   DETERMINATION OF ANIONIC IMPURITIES IN SELECTED CONCENTRATED ELECTROLYTES BY ION CHROMATOGRAPHY [J].
COX, JA ;
TANAKA, N .
ANALYTICAL CHEMISTRY, 1985, 57 (01) :383-385
[3]   ION-EXCHANGE TREATMENT OF COMPLICATED SAMPLES PRIOR TO ION CHROMATOGRAPHIC ANALYSIS [J].
COX, JA ;
DABEKZLOTORZYNSKA, E ;
SAARI, R ;
TANAKA, N .
ANALYST, 1988, 113 (09) :1401-1404
[4]   ION CHROMATOGRAPHY [J].
FRITZ, JS .
ANALYTICAL CHEMISTRY, 1987, 59 (04) :A335-&
[5]   ELECTRODIALYSIS FOR CLEANUP OF STRONGLY ALKALINE SAMPLES IN ION CHROMATOGRAPHY [J].
HADDAD, PR ;
LAKSANA, S ;
SIMONS, RG .
JOURNAL OF CHROMATOGRAPHY, 1993, 640 (1-2) :135-143
[6]  
HENSHALL A, 1992, AM LAB, V24, pR20
[7]  
*INST INSTR TROUB, 1992, 034528 INST INSTR TR
[8]   DIALYTIC CLEANUP OF ALKALINE SAMPLES PRIOR TO ION CHROMATOGRAPHIC ANALYSIS [J].
LAKSANA, S ;
HADDAD, PR .
JOURNAL OF CHROMATOGRAPHY, 1992, 602 (1-2) :57-63
[9]   Influence of the sample matrix composition on the accuracy of the ion chromatographic determination of anions [J].
Novic, M ;
Divjak, B ;
Pihlar, B ;
Hudnik, V .
JOURNAL OF CHROMATOGRAPHY A, 1996, 739 (1-2) :35-42
[10]   NEW MEMBRANE-BASED ELECTROLYTIC SUPPRESSOR DEVICE FOR SUPPRESSED CONDUCTIVITY DETECTION IN ION CHROMATOGRAPHY [J].
RABIN, S ;
STILLIAN, J ;
BARRETO, V ;
FRIEDMAN, K ;
TOOFAN, M .
JOURNAL OF CHROMATOGRAPHY, 1993, 640 (1-2) :97-109