Precision of measurements of physical workload during standardized manual handling part III: Goniometry of the wrists

被引:20
作者
Balogh, I. [1 ]
Ohlsson, K. [1 ]
Nordander, C. [1 ]
Skerfving, S. [1 ]
Hansson, G. -A [1 ]
机构
[1] Univ Hosp, Dept Occupat & Environm Med, S-22185 Lund, Sweden
基金
英国医学研究理事会;
关键词
Intra-subjects; Inter-subjects; Exposure variability; Assembly work; MUSCULOSKELETAL DISORDERS; MEASUREMENT ACCURACY; UPPER BACK; NECK; MOVEMENTS; TASK; EXPOSURE; HEAD; ARMS;
D O I
10.1016/j.jelekin.2008.07.003
中图分类号
Q189 [神经科学];
学科分类号
071006 [神经生物学];
摘要
Goniometry of the wrist is a feasible method for studying wrist movements in most hand-intensive work. The precision and accuracy of the method per se is good. For the knowledge on validity of field measurements, the size of imprecision is of importance. This study evaluated this condition during standardized circumstances. Six women performed three different hand-intensive work tasks: 'materials picking', 'light assembly', and 'heavy assembly', repeated during three different days. Variance components between-days (within subjects) and between-subjects were derived for positions (flexion/extension and deviation) and movements, including angular velocities, % of time with very low velocity (<1 degrees/s), as well as repetitiveness. For positions, the average standard deviations in the three tasks were, both between-days and between-subjects, 3-4 degrees. For movements, the coefficients of variation of angular velocities were about 10% between-days, and could to a great part be explained by differences in work rate. Between-subjects variability was higher, 20-40%. The variability was larger at low velocities than at high ones. The precision of the measured positions was good, expressed as small between-days and between-subjects variability. For movements, the between-days variability was also small, while there was a larger between-subjects variability. The imprecision of goniometry is consequently lower and comparable with inclinometry but lower than for EMG. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1005 / 1012
页数:8
相关论文
共 25 条
[1]
[Anonymous], ADV OCCUP MED REHABI
[2]
Changes in physical workload with implementation of mouse-based information technology in air traffic control [J].
Arvidsson, Inger ;
Hansson, Gert-Ake ;
Mathiassen, Svend Erik ;
Skerfving, Staffan .
INTERNATIONAL JOURNAL OF INDUSTRIAL ERGONOMICS, 2006, 36 (07) :613-622
[3]
Interindividual variation of physical load in a work task [J].
Balogh, I ;
Hansson, GÅ ;
Ohlsson, K ;
Strömberg, U ;
Skerfving, S .
SCANDINAVIAN JOURNAL OF WORK ENVIRONMENT & HEALTH, 1999, 25 (01) :57-66
[4]
BERNARD BP, 1997, MUSCULOSKELETAL DISO, P997
[5]
Practical operation of a biaxial goniometer at the wrist joint [J].
Buchholz, B ;
Wellman, H .
HUMAN FACTORS, 1997, 39 (01) :119-129
[6]
Ergonomics and musculoskeletal disorders: overview [J].
Buckle, P .
OCCUPATIONAL MEDICINE-OXFORD, 2005, 55 (03) :164-167
[7]
The nature of work-related neck and upper limb musculoskeletal disorders [J].
Buckle, PW ;
Devereux, JJ .
APPLIED ERGONOMICS, 2002, 33 (03) :207-217
[8]
Physical workload on neck and upper limb using two CAD applications [J].
Byström, JU ;
Hansson, GÅ ;
Rylander, L ;
Ohlsson, K ;
Källrot, G ;
Skerfving, S .
APPLIED ERGONOMICS, 2002, 33 (01) :63-74
[9]
THE VALIDITY OF VISUAL OBSERVATION TO ASSESS POSTURE IN A LABORATORY-SIMULATED, MANUAL MATERIAL HANDLING TASK [J].
DELOOZE, MP ;
TOUSSAINT, HM ;
ENSINK, J ;
MANGNUS, C ;
VANDERBEEK, AJ .
ERGONOMICS, 1994, 37 (08) :1335-1343
[10]
Optimal digital filtering requires a different cut-off frequency strategy for the determination of the higher derivatives [J].
Giakas, G ;
Baltzopoulos, V .
JOURNAL OF BIOMECHANICS, 1997, 30 (08) :851-855