Routine testing of magnetic field homogeneity on clinical MRI systems

被引:25
作者
Chen, Hua-Hsuan [1 ]
Boykin, Rex D.
Clarke, Geoffrey D.
Gao, Jia-Hong T.
Roby, John W., III
机构
[1] Univ Texas, Hlth Sci Ctr, Dept Radiol, San Antonio, TX 78284 USA
[2] Univ Texas, Hlth Sci Ctr, Res Imaging Ctr, San Antonio, TX 78284 USA
关键词
magnetic resonance imaging; phantoms; magnetic fields;
D O I
10.1118/1.2359229
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Poor main magnetic field (B-0) homogeneity (H-B) leads to artifacts and signal losses in magnetic resonance imaging (MRI). The American College of Radiology's MRI quality control manual mandates annual checks of H-B, suggesting tests using spectral linewidth and phase-difference (Delta phi) maps. A new method, the bandwidth-difference (Delta BW) method, which compares the distortion for small and large BW acquisitions to determine the H-B, is proposed. The Delta BW method has the advantage that it can be used to measure multiple diameters of spherical volumes (DSV) in a single phantom. A phantom has been developed to exploit this method and results obtained with it are compared to those using three standard methods. Small receiver BW in the presence of poor H-B leads to geometric distortions because gradients are reduced to the level of the B-0 inhomogeneities. Data were acquired using seven MRI systems from different manufacturers, ranging in field strength from 0.2 to 3.0 T. Fast gradient echo pulse sequences were scanned twice using small and large BWs. H-B was measured from the shift of landmarks between the two BW acquisitions. Results were compared with data from the full width at half maximum (FWHM) method, the Delta phi method and one manufacturer's resonant frequency mapping data. The FWHM method was available on two systems and the Delta method was available on one. The Delta phi method could be performed in all scanners investigated. The H-B measured ranged 0.11 - 0.32 ppm to 6.7 - 12.9 ppm for DSV of 13 - 22.6 cm. Direct comparisons of the data obtained using the Delta BW method showed good agreement with data obtained using the FWHM method. Data obtained using the Delta phi method compared favorably with the manufacturer's resonant frequency map. The Delta BW method produces measurements of H-B at various DSV values that can be obtained from a single set of phantom images. The accuracy of Delta BW B-0 homogeneity measurements are comparable to the other methods tested. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:4299 / 4306
页数:8
相关论文
共 14 条
[1]
MULTINUCLEAR NMR INVESTIGATIONS OF PROBE CONSTRUCTION MATERIALS AT 4.7-T [J].
BABCOCK, EE ;
VAUGHAN, JT ;
LESAN, B ;
NUNNALLY, RL .
MAGNETIC RESONANCE IN MEDICINE, 1990, 13 (03) :498-503
[2]
CHEN CN, 1989, BIOMEDICAL MAGNETIC, P84
[3]
CHU SCK, 1990, MAGN RESON MED, V13, P239, DOI 10.1002/mrm.1910130207
[4]
DEGRAAF RA, 1998, IN VIVO NMR SPECTROS, P15
[5]
Proton magnetic resonance spectroscopy in the brain: report of AAPM MR task group #9 [J].
Drost, DJ ;
Riddle, WR ;
Clarke, GD .
MEDICAL PHYSICS, 2002, 29 (09) :2177-2197
[6]
QUALITY ASSESSMENT IN IN-VIVO NMR-SPECTROSCOPY .3. CLINICAL-TEST OBJECTS - DESIGN, CONSTRUCTION, AND SOLUTIONS [J].
LEACH, MO ;
COLLINS, DJ ;
KEEVIL, S ;
ROWLAND, I ;
SMITH, MA ;
HENRIKSEN, O ;
BOVEE, WMMJ ;
PODO, F .
MAGNETIC RESONANCE IMAGING, 1995, 13 (01) :131-137
[7]
LI BJ, 1996, MAGN RESON MED, V36, P705
[8]
MITCHELL M D, 1986, Magnetic Resonance Imaging, V4, P263, DOI 10.1016/0730-725X(86)91068-4
[9]
The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds [J].
Schenck, JF .
MEDICAL PHYSICS, 1996, 23 (06) :815-850
[10]
IMAGE-RESTORATION FROM NON-UNIFORM MAGNETIC-FIELD INFLUENCE FOR DIRECT FOURIER NMR IMAGING [J].
SEKIHARA, K ;
KURODA, M ;
KOHNO, H .
PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (01) :15-24