Early Failure of Cementless Porous Tantalum Monoblock Tibial Components

被引:60
作者
Meneghini, R. Michael [1 ]
de Beaubien, Brian C. [2 ]
机构
[1] Indiana Univ Sch Med, Indiana Univ Hlth Phys, Indianapolis, IN 46202 USA
[2] Michigan Hip & Knee Replacement, Saginaw, MI USA
关键词
failure; cementless; uncemented; total knee replacement; total knee arthroplasty; tibia; tantalum; TOTAL KNEE ARTHROPLASTY; TERM FOLLOW-UP; TRABECULAR METAL; REPLACEMENT; OSTEOLYSIS; SURVIVORSHIP; BIOMATERIAL; PROSTHESES; FIXATION; REVISION;
D O I
10.1016/j.arth.2013.03.005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Patient selection for cementless knee arthroplasty (TKA) remains challenging. 106 consecutive TKAs performed with a cementless porous tantalum tibial component of PS-design were reviewed. Nine failures (8 male/1 female) occurred at a mean 18 months and demonstrated a characteristic failure mode of medial tibial collapse. The mean height of 72.5 inches in the failure group was greater than the 65.8 inches in the well-functioning group (P < 0.001). The mean weight of 260.4 lb in the failure group was greater than the 204.1 lb in the well-functioning group (P = 0.006). The high early failure rate occurred predominantly in tall, heavy, male patients and may be related to medial tibial overload resulting from increased flexibility of the implant in this patient type. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:1505 / 1508
页数:4
相关论文
共 36 条
[1]
[Anonymous], J ARTHROPLASTY
[2]
Berger RA, 2001, CLIN ORTHOP RELAT R, P58
[3]
Berger RA, 2001, CLIN ORTHOP RELAT R, P196
[4]
Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial [J].
Bobyn, JD ;
Stackpool, GJ ;
Hacking, SA ;
Tanzer, M ;
Krygier, JJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (05) :907-914
[5]
Clinical validation of a structural porous tantalum biomaterial for adult reconstruction [J].
Bobyn, JD ;
Poggie, RA ;
Krygier, JJ ;
Lewallen, DG ;
Hanssen, AD ;
Lewis, RJ ;
Unger, AS ;
O'Keefe, TJ ;
Christie, MJ ;
Nasser, S ;
Wood, JE ;
Stulberg, SD ;
Tanzer, M .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A :123-129
[6]
Cohen Robert, 2002, Am J Orthop (Belle Mead NJ), V31, P216
[7]
Deshmane PP, 2012, AM AC ORTH SURG MARC
[8]
FAILURE OF TOTAL KNEE ARTHROPLASTY DUE TO LOOSENING AND DEFORMATION OF TIBIAL COMPONENT [J].
DUCHEYNE, P ;
KAGAN, A ;
LACEY, JA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1978, 60 (03) :384-391
[9]
Fixation of a Trabecular Metal Knee Arthroplasty Component A Prospective Randomized Study [J].
Dunbar, M. J. ;
Wilson, D. A. J. ;
Hennigar, A. W. ;
Amirault, J. D. ;
Gross, M. ;
Reardon, G. P. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (07) :1578-1586
[10]
ENGH GA, 1994, CLIN ORTHOP RELAT R, P33