摘要
Substantial improvements in the selectivity of electrochemical measurements of trace nucleic adds are obtained by using membrane-covered carbon disk electrodes. Access to the electrode surface can be manipulated via a judicious choice of the membrane molecular weight cutoff (MWCO). The resulting separation step, performed in situ at the electrode surface, adds a new dimension of selectivity based on molecular size to electroanalysis of nucleic acids, Transport properties are evaluated with respect to the oligonucleotide length and membrane MWCO. A highly selective response is observed for synthetic oligonucleotides in the presence of otherwise interfering chromosomal DNAs. Discrimination among oligonucleotides of different lengths is also possible, Short accumulation periods (1-5 min) are sufficient for convenient measurements of low milligram per liter concentrations.
引用
收藏
页码:4056 / 4059
页数:4
相关论文
共 17 条
[1]   OXIDATION OF DEOXYRIBONUCLEIC-ACID AT CARBON ELECTRODES - THE EFFECT OF THE QUALITY OF THE DEOXYRIBONUCLEIC-ACID SAMPLE [J].
BRABEC, V ;
KOUDELKA, J .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1980, 7 (04) :793-805
[2]   Evaluation of different carbon electrodes for adsorptive stripping analysis of nucleic acids [J].
Cai, XH ;
Rivas, G ;
Farias, PAM ;
Shiraishi, H ;
Wang, J ;
Palecek, E .
ELECTROANALYSIS, 1996, 8 (8-9) :753-758
[3]   USE OF POLYMER-FILMS IN AMPEROMETRIC BIOSENSORS [J].
EMR, SA ;
YACYNYCH, AM .
ELECTROANALYSIS, 1995, 7 (10) :913-923
[4]   APPLICATION OF POLYMER-COATED GLASSY-CARBON ELECTRODES IN ANODIC-STRIPPING VOLTAMMETRY [J].
HOYER, B ;
FLORENCE, TM ;
BATLEY, GE .
ANALYTICAL CHEMISTRY, 1987, 59 (13) :1608-1614
[5]  
MANIATI T, 1982, MOL CLONING LAB MANU
[6]   CHEMICALLY MODIFIED ELECTRODES - MOLECULAR DESIGN FOR ELECTROANALYSIS [J].
MURRAY, RW ;
EWING, AG ;
DURST, RA .
ANALYTICAL CHEMISTRY, 1987, 59 (05) :A379-&
[8]   From polarography of DNA to microanalysis with nucleic acid-modified electrodes [J].
Palecek, E .
ELECTROANALYSIS, 1996, 8 (01) :7-14
[9]   DIFFERENTIAL-PULSE VOLTAMMETRIC DETERMINATION OF RNA AT THE PICOMOLE LEVEL IN THE PRESENCE OF DNA AND NUCLEIC-ACID [J].
PALECEK, E ;
FOJTA, M .
ANALYTICAL CHEMISTRY, 1994, 66 (09) :1566-1571
[10]   ELECTROCHEMICAL ANALYSIS OF THE SELF-COMPLEMENTARY B-DNA DECAMER D(CCAGGCCTGG) [J].
PALECEK, E ;
KOLAR, V ;
JELEN, F ;
HEINEMANN, U .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1990, 23 (03) :285-299