The dosimetric consequences of inter-fractional patient movement on conventional and intensity-modulated breast radiotherapy treatments

被引:63
作者
Hector, CL
Webb, S
Evans, PM
机构
[1] Inst Canc Res, Joint Dept Phys, Sutton SM2 5PT, Surrey, England
[2] Royal Marsden NHS Trust, Sutton SM2 5PT, Surrey, England
基金
英国医学研究理事会;
关键词
radiotherapy; breast cancer; intensity-modulated beams; patient movement;
D O I
10.1016/S0167-8140(99)00167-X
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: A method has been developed to enable a comparison to be made between the effects of movement on conventional tangential breast treatments and intensity-modulated treatments delivered using compensators. Materials and methods: The effects of set-up error and organ motion were studied for a set of six patients. Images were taken of these patients over the course of their treatment and conventional wedged and compensated treatment plans were designed for each. Dose-volume statistics were used to evaluate each of the treatment plans by examining the volume outside the dose range 95-105%. To assess the effects of movement alone, the volume change from day 1 was also calculated. Results: Thirty-six estimated CT-sets were available for evaluation. Measurements of breast volume showed the volume to increase to a peak between fraction 4 and 8 and then decrease back below the initial volume. The standard treatment was found to yield 29/36 plans (81%) with greater than 5% volume outside the dose range 95-105%. For the compensated plans this dropped to 11/36 plans (31%). The analysis of the volume changes from day 1 showed that for both standard and compensated treatments 7/30 plans (23%) had an increase in volume outside the dose range 95-105% of greater than 5% of the total planning target volume. Conclusions: The compensated treatment is more susceptible to patient movement. However, the actual volume of tissue outside 95-105% dose is less when compared to standard treatment implying the compensated treatment is still superior. (C) 2000 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:57 / 64
页数:8
相关论文
共 21 条
[1]  
[Anonymous], P 11 INT C US COMP R
[2]   A STUDY OF EFFECTIVE ATTENUATION COEFFICIENT FOR CALCULATING TISSUE COMPENSATOR THICKNESS [J].
BAGNE, FR ;
SAMSAMI, N ;
HOKE, SW ;
BRONN, DG .
MEDICAL PHYSICS, 1990, 17 (01) :117-121
[3]   COMPENSATING FILTERS FOR HIGH-ENERGY X-RAYS [J].
BOYER, AL .
MEDICAL PHYSICS, 1982, 9 (03) :429-433
[4]   The use of an optical outlining system for weekly on-set verification of patients with carcinoma of the breast [J].
Casebow, MP ;
Harris, RL ;
Jarvis, RJ .
RADIOTHERAPY AND ONCOLOGY, 1998, 46 (01) :99-103
[5]   COMPENSATING FILTER DESIGN USING MEGAVOLTAGE RADIOGRAPHY [J].
DIXON, RL ;
EKSTRAND, KE ;
FERREE, C .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1979, 5 (02) :281-287
[6]   DESIGN OF COMPENSATORS FOR BREAST RADIOTHERAPY USING ELECTRONIC PORTAL IMAGING [J].
EVANS, PM ;
HANSEN, VN ;
MAYLES, WPM ;
SWINDELL, W ;
TORR, M ;
YARNOLD, JR .
RADIOTHERAPY AND ONCOLOGY, 1995, 37 (01) :43-54
[7]   Practical implementation of compensators in breast radiotherapy [J].
Evans, PM ;
Donovan, EM ;
Fenton, N ;
Hansen, VN ;
Moore, I ;
Partridge, M ;
Reise, S ;
Suter, B ;
Symonds-Tayler, JRN ;
Yarnold, JR .
RADIOTHERAPY AND ONCOLOGY, 1998, 49 (03) :255-265
[8]   COMPUTER-AIDED DESIGN AND VERIFICATION OF MEGAVOLTAGE TISSUE COMPENSATORS FOR OBLIQUE BEAMS [J].
FADDEGON, BA ;
PFALZNER, P .
MEDICAL PHYSICS, 1988, 15 (05) :757-762
[9]   Intra- and interfractional reproducibility of tangential breast fields: A prospective on-line portal imaging study [J].
Fein, DA ;
McGee, KP ;
Schultheiss, TE ;
Fowble, BL ;
Hanks, GE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 34 (03) :733-740
[10]  
GOITEIN M, 1982, PROGR MED RAD PHYSIC, V1, P195