A new approach to computer-aided spine surgery: fluoroscopy-based surgical navigation

被引:102
作者
Nolte, LP
Slomczykowski, MA
Berlemann, U
Strauss, MJ
Hofstetter, R
Schlenzka, D
Laine, T
Lund, T
机构
[1] Univ Bern, ME Muller Inst Biomech, CH-3010 Bern, Switzerland
[2] Univ Bern, Inselspital, Dept Orthoped Surg, CH-3010 Bern, Switzerland
[3] Univ Clin Eppendorf, Dept Orthoped Surg, Hamburg, Germany
[4] ORTON Orthoped Hosp, Invalid Fdn Helsinki, Helsinki, Finland
关键词
spine; implant; pedicle screws; navigation; fluoroscopy;
D O I
10.1007/PL00010026
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
A new computer-based navigation system for spinal surgery has been designed. This was achieved by combining intraoperative fluoroscopy-based imaging using conventional C-arm technology with free-hand surgical navigation principles. Modules were developed to automate digital X-ray image registration. This is in contrast to existing computed tomography-(CT) based spinal navigation systems, which require a vertebra-based registration procedure. Cross-referencing of the image intensifier with the surgical object allows the real-time image-interactive navigation of surgical tools based on one single registered X-ray image, with no further image updates. Furthermore, the system allows the acquisition and real-time use of multiple registered images, which provides an advanced multi-directional control (pseudo 3D) during surgical action. Stereotactic instruments and graphical user interfaces for image-interactive transpedicular screw insertion have been developed. A detailed validation of the system was performed in the laboratory setting and throughout an early clinical trial including eight patients in two spine centers. Based on the resulting data, the new technique promises improved accuracy and safety in open and percutaneous spinal surgery.
引用
收藏
页码:S78 / S88
页数:11
相关论文
共 43 条
[1]  
[Anonymous], P INT S COMP ASS RAD
[2]  
[Anonymous], BRIT MED J
[3]  
Berlemann U, 1997, J SPINAL DISORD, V10, P117
[4]   ANALYSIS AND CORRECTION OF IMPERFECTIONS IN THE IMAGE INTENSIFIER-TV-DIGITIZER IMAGING CHAIN [J].
BOONE, JM ;
SEIBERT, JA ;
BARRETT, WA ;
BLOOD, EA .
MEDICAL PHYSICS, 1991, 18 (02) :236-242
[5]  
BOWERSOX JC, 1997, J COMP AIDED SURG, V2, P69
[6]  
BRANDT G, 1997, P COMP VIS VIRT REAL, P767
[7]   COMPUTER-ASSISTED MEDICAL INTERVENTIONS - PASSIVE AND SEMIACTIVE AIDS [J].
CINQUIN, P ;
BAINVILLE, E ;
BARBE, C ;
BITTAR, E ;
BOUCHARD, V ;
BRICAULT, I ;
CHAMPLEBOUX, G ;
CHENIN, M ;
CHEVALIER, L ;
DELNONDEDIEU, Y ;
DESBAT, L ;
DESSENNE, V ;
HAMADEH, A ;
HENRY, D ;
LAIEB, N ;
LAVALLEE, S ;
LEFEBVRE, JM ;
LEITNER, F ;
MENGUY, Y ;
PADIEU, F ;
PERIA, O ;
POYET, A ;
PROMAYON, M ;
ROUAULT, S ;
SAUTOT, P ;
TROCCAZ, J ;
VASSAL, P .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1995, 14 (03) :254-263
[8]   COMPLICATIONS ASSOCIATED WITH THE TECHNIQUE OF PEDICLE SCREW FIXATION - A SELECTED SURVEY OF ABS MEMBERS [J].
ESSES, SI ;
SACHS, BL ;
DREYZIN, V .
SPINE, 1993, 18 (15) :2231-2239
[9]  
FOLEY KT, 1997, P S COMP ASS ORTH SU, P85
[10]  
GEMBRAN KD, 1988, IEEE INT C ROB AUT, P562