Power Doppler harmonic imaging: A feasibility study of a new technique for the assessment of myocardial perfusion

被引:57
作者
Senior, R
Kaul, S
Soman, P
Lahiri, A
机构
[1] Northwick Pk Hosp, Dept Cardiovasc Med, Harrow HA1 3UJ, Middx, England
[2] Inst Med Res, Harrow, Middx, England
[3] Univ Virginia, Sch Med, Charlottesville, VA 22903 USA
关键词
D O I
10.1016/S0002-8703(00)90233-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The aim of the study was to assess the feasibility of a! new technique, power Doppler harmonic imaging (PDHI)I for assessing myocardial perfusion through a venous injection of microbubbles, with the use of a new ultrasound contrast agent. Methods and Results Fifteen patients with known coronary artery disease and a resting perfusion abnormality on Tc-99m sestamibi single-photon emission computed tomography (SPECT) underwent PDHI at rest during intravenous injections: of 2 to 3 mi of Sonovue (Bracco SpA, Milan, Italy), a new second-generation ultrasound contrast agent. Myocardial perfusion was determined to be present or absent by use of a 5-segment model by 2 blinded observers for both PDHI and SPECT Of a total of 75 possible myocardial segments, 7 (9%) were not analyzed because of obvious artifacts on PDHI. SPECT:showed perfusion defects in 40 of the remaining 68 segments, whereas PDHI showed 39 defects. There was high concordance between the 2 imaging modalities for the presence (93%) as well as the location (96% for the anteroseptal region, 93% for the inferoposterior region, and 87% for the apical region) of the defects. Conclusions These preliminary results suggest that PDHI is a feasible technique for the detection of resting myocardial perfusion defects in patients with coronary artery disease after a venous injection of a new second-generation ultrasound contrast agent.
引用
收藏
页码:245 / 251
页数:7
相关论文
共 15 条
[1]  
Burns PN, 1996, CLIN RADIOL, V51, P50
[2]   Optical and acoustical observations of the effects of ultrasound on contrast agents [J].
Dayton, PA ;
Morgan, KE ;
Klibanov, AL ;
Brandenburger, GH ;
Ferrara, KW .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (01) :220-232
[3]  
FIROOZAN S, 1999, AM J PHYSIOL, V45, pH464
[4]   Effects of myocardial fiber orientation in echocardiography: Quantitative measurements and computer simulation of the regional dependence of backscattered ultrasound in the parasternal short-axis view [J].
Holland, MR ;
Wilkenshoff, UM ;
Finch-Johnston, AE ;
Handley, SM ;
Perez, JE ;
Miller, JG .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1998, 11 (10) :929-937
[5]  
Kaul S, 1997, CIRCULATION, V96, P3745
[6]  
Kaul S, 1997, CIRCULATION, V96, P785
[7]  
KAUL S, 1997, CURR PROB CARDIOLOGY, V22, P553
[8]   CLINICAL BIOSTATISTICS .54. THE BIOSTATISTICS OF CONCORDANCE [J].
KRAMER, MS ;
FEINSTEIN, AR .
CLINICAL PHARMACOLOGY & THERAPEUTICS, 1981, 29 (01) :111-123
[9]   Enhancement of left ventricular cavity opacification by harmonic imaging after venous injection of Albunex [J].
Lindner, JR ;
Dent, JM ;
Moos, SP ;
Jayaweera, AR ;
Kaul, S .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (12) :1657-1662
[10]   Potential advantage of flash echocardiography for digital subtraction of B-mode images acquired during myocardial contrast echocardiography [J].
Pelberg, RA ;
Wei, K ;
Kamiyama, N ;
Sklenar, J ;
Bin, JP ;
Kaul, S .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1999, 12 (02) :85-93