Optimization of an electrolyte conductivity detector for measuring low ion concentrations

被引:53
作者
Timmer, B [1 ]
Sparreboom, W [1 ]
Olthuis, W [1 ]
Bergveld, P [1 ]
van den Berg, A [1 ]
机构
[1] Univ Twente, MESA Res Inst, NL-7500 AE Enschede, Netherlands
来源
LAB ON A CHIP | 2002年 / 2卷 / 02期
关键词
D O I
10.1039/b201225a
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The optimization process of a planar interdigitated conductivity detector for measuring very low electrolyte concentrations for use in a lab-on-chip gas detection system is described. An electrical equivalent of the sensor is given, which includes the double layer capacitance dependency on the electrolyte concentration, resulting in a better description of the impedance of the sensor. The cell constant of the sensor is minimized to reduce the cell resistance in low specific conductivity solutions under the restriction of a small electrode area (less than or equal to 0.1 cm(2)) for fast measurement, prescribed by the ammonia detection system. The small size makes it suitable for integration in micro channels. The developed sensor has a cell constant of 7.9 m(-1) resulting in a maximum resistance for deionized water of 177 kOmega at a frequency of 1 kHz.
引用
收藏
页码:121 / 124
页数:4
相关论文
共 18 条
  • [1] Bard A. J., 1980, ELECTROCHEMICAL METH
  • [2] Instrument development and application in studies and monitoring of ambient ammonia
    Erisman, JW
    Otjes, R
    Hensen, A
    Jongejan, P
    van den Bulk, P
    Khlystov, A
    Möls, H
    Slanina, S
    [J]. ATMOSPHERIC ENVIRONMENT, 2001, 35 (11) : 1913 - 1922
  • [3] Guijt RM, 2001, ELECTROPHORESIS, V22, P235, DOI 10.1002/1522-2683(200101)22:2<235::AID-ELPS235>3.0.CO
  • [4] 2-O
  • [5] DESIGN OPTIMIZATION OF PLANAR ELECTROLYTIC CONDUCTIVITY SENSORS
    JACOBS, P
    VARLAN, A
    SANSEN, W
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1995, 33 (06) : 802 - 810
  • [6] LAMBRECHTS M, 1992, BIOSENSORS MICROELEC, pCH2
  • [7] A non-primitive model for the electrode|electrolyte interface based on the Percus-Yevick theory.: Analysis of the different molecular sizes, ion valences and electrolyte concentrations
    Lamperski, S
    Outhwaite, CW
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 460 (1-2): : 135 - 143
  • [8] A demonstration of acquiring specific concentration data by variations in the operating conditions of a non-specific sensor
    Langereis, GR
    Olthuis, W
    Bergveld, P
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2000, 50 (02) : 211 - 223
  • [9] LANGEREIS GR, 1999, THESIS U TWENTE
  • [10] Conductivity detection for monitoring mixing reactions in microfluidic devices
    Liu, Y
    Wipf, DO
    Henry, CS
    [J]. ANALYST, 2001, 126 (08) : 1248 - 1251