Purpose: To evaluate the effects of beam weight optimization for 3D conformal radiotherapy plans, with or without beam intensity modulation, in Stage III non-small cell lung cancer (NSCLC), Methods and Materials: Ten patients with Stage III NSCLC were planned using a conventional 3D technique and a technique involving noncoplanar beam intensity modulation (BIM), Two planning target volumes (PTVs) were defined: PTV1 included macroscopic tumor volume and PTV2 included macroscopic and microscopic tumor volume. Virtual simulation defined the beam shapes and incidences as well as the wedge orientations (3D) and segment outlines (BIM), Weights of wedged beams, unwedged beams, and segments were determined by human trial and error for the SD-plans (3D-manual), by a standard weight table (SWT) for the BIM-plans (BIM-SWT) and by optimization (SD-optimized and BIM-optimized) using an objective function with a biological and a physical component. The resulting non-optimized and optimized dose distributions were compared, using physical endpoints, after normalizing the median dose of PTV1 to 80 Gy, Results: Optimization improved dose homogeneity at the target for 3D- and BIM-plans and the minimum dose at PTV1. The minimum dose at PTV2 was decreased by optimization especially in 3D-plans, After optimization, the dose-volume histograms (DVHs) of lung and heart were shifted to lower doses for 80-90% of the organ volume. Since lung is the dose-limiting organ in Stage III NSCLC, an increased minimum dose at PTV1 together with a decreased dose at the main lung volume suggests an improved therapeutic ratio. Optimization allows 10% dose escalation for 3D-plans and 20% for BIM-plans at isotoxicity levels of lung and spinal cord. Upon dose escalation, esophagus may become the dose-limiting structure when PTV1 extends close to the esophagus, Conclusions: Optimization using a biophysical objective function allowed an increase of the therapeutic ratio of radiotherapy planning for Stage III NSCLC. (C) 2000 Elsevier Science Inc.
引用
收藏
页码:255 / 260
页数:6
相关论文
共 19 条
[1]   Promising survival with three-dimensional conformal radiation therapy for non-small cell lung cancer [J].
Armstrong, J ;
Raben, A ;
Zelefsky, M ;
Burt, M ;
Leibel, S ;
Burman, C ;
Kutcher, G ;
Harrison, L ;
Hahn, C ;
Ginsberg, R ;
Rusch, V ;
Kris, M ;
Fuks, Z .
RADIOTHERAPY AND ONCOLOGY, 1997, 44 (01) :17-22
[2]  
BATHO H F, 1964, J Can Assoc Radiol, V15, P79
[3]  
Brent R, 1973, ALGORITHM MINIMIZATI
[4]   FITTING OF NORMAL TISSUE TOLERANCE DATA TO AN ANALYTIC-FUNCTION [J].
BURMAN, C ;
KUTCHER, GJ ;
EMAMI, B ;
GOITEIN, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (01) :123-135
[5]   THE EVOLUTION OF RADIATION-THERAPY ONCOLOGY GROUP (RTOG) PROTOCOLS FOR NONSMALL CELL LUNG-CANCER [J].
BYHARDT, RW .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 32 (05) :1513-1525
[6]   PROGNOSTIC FACTORS IN LOCOREGIONAL NONSMALL CELL LUNG-CANCER TREATED WITH RADIOTHERAPY [J].
COEN, V ;
VANLANCKER, M ;
DENEVE, W ;
STORME, G .
AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 1995, 18 (02) :111-117
[7]   Non-coplanar beam intensity modulation allows large dose escalation in stage III lung cancer [J].
Derycke, S ;
Van Duyse, B ;
De Gersem, W ;
De Wagter, C ;
De Neve, W .
RADIOTHERAPY AND ONCOLOGY, 1997, 45 (03) :253-261
[8]  
FLETCHER GH, 1973, BRIT J RADIOL, V46, P1
[9]   Preliminary results of a prospective trial using three dimensional radiotherapy for lung cancer [J].
Graham, MV ;
Purdy, JA ;
Emami, B ;
Matthews, JW ;
Harms, WB .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :993-1000
[10]   RESULTS OF HIGH-DOSE THORACIC IRRADIATION INCORPORATING BEAMS EYE VIEW DISPLAY IN NONSMALL CELL LUNG-CANCER - A RETROSPECTIVE MULTIVARIATE-ANALYSIS [J].
HAZUKA, MB ;
TURRISI, AT ;
LUTZ, ST ;
MARTEL, MK ;
TENHAKEN, RK ;
STRAWDERMAN, M ;
BOREMA, PL ;
LICHTER, AS .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (02) :273-284