In vivo and ex vivo SPME: a low invasive sampling and sample preparation tool in clinical bioanalysis

被引:46
作者
Bojko, Barbara [1 ,2 ]
Pawliszyn, Janusz [1 ]
机构
[1] Univ Waterloo, Dept Chem, Waterloo, ON N2L 3G1, Canada
[2] Nicolaus Copernicus Univ Torun, Dept Med Chem, Coll Med Bydgoszcz, PL-85094 Bydgoszcz, Poland
基金
加拿大自然科学与工程研究理事会;
关键词
SOLID-PHASE MICROEXTRACTION; VOLATILE ORGANIC-COMPOUNDS; CHROMATOGRAPHY-MASS SPECTROMETRY; PERFORMANCE LIQUID-CHROMATOGRAPHY; GEL TECHNIQUE PRIOR; LUNG-CANCER; HUMAN BREATH; URINARY 8-HYDROXY-2'-DEOXYGUANOSINE; ALTERNATIVE MATRIX; AUTOMATED-ANALYSIS;
D O I
10.4155/bio.14.91
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
Solid phase microextraction (SPME) is well-established technology in bioanalysis. Current review discusses the features of SPME, which determine the non- or low-invasiveness of the method in biomedical analysis. In the first section we analyze the factors, which have significant influence on the SPME sampling device performance in the view of sampling safety and efficiency. In the later sections applicability of various SPME approaches for analysis of easily accessible samples routinely used for analysis (e.g., urine, blood) as well as limited availability samples (tissues) is discussed. Moreover, the examples of sampling alternative matrices such as hair, saliva, sweat or breath are presented. The advantages and limitation of the technology in the view of future development of SPME are also reviewed.
引用
收藏
页码:1227 / 1239
页数:13
相关论文
共 108 条
[1]
Comparative analysis of volatile metabolomics signals from melanoma and benign skin: a pilot study [J].
Abaffy, T. ;
Moeller, M. G. ;
Riemer, D. D. ;
Milikowski, C. ;
DeFazio, R. A. .
METABOLOMICS, 2013, 9 (05) :998-1008
[2]
Differential Volatile Signatures from Skin, Naevi and Melanoma: A Novel Approach to Detect a Pathological Process [J].
Abaffy, Tatjana ;
Duncan, Robert ;
Riemer, Daniel D. ;
Tietje, Olaf ;
Elgart, George ;
Milikowski, Clara ;
DeFazio, R. Anthony .
PLOS ONE, 2010, 5 (11)
[3]
Simultaneous detection of seventeen drugs of abuse and metabolites in hair using solid phase micro extraction (SPME) with GC/MS [J].
Aleksa, Katarina ;
Walasek, Paula ;
Fulga, Netta ;
Kapur, Bhushan ;
Gareri, Joey ;
Koren, Gideon .
FORENSIC SCIENCE INTERNATIONAL, 2012, 218 (1-3) :31-36
[4]
Determination of cocaine and cocaethylene in plasma by solid-phase microextraction and gas chromatography-mass spectrometry [J].
Alvarez, Ivan ;
Bermejo, Ana Maria ;
Tabernero, Maria Jesus ;
Fernandez, Purificacion ;
Lopez, Patricia .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 845 (01) :90-94
[5]
Analysis of tricyclic antidepressant drugs in plasma by means of solid-phase microextraction-liquid chromatography-mass spectrometry [J].
Alves, Claudete ;
Santos-Neto, Alvaro J. ;
Fernandes, Christian ;
Rodrigues, Jose C. ;
Lancas, Fernando M. .
JOURNAL OF MASS SPECTROMETRY, 2007, 42 (10) :1342-1347
[6]
SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[7]
Barbosa J, 2013, BIOANALYSIS, V5, P895, DOI [10.4155/BIO.13.50, 10.4155/bio.13.50]
[8]
Application of solid phase microextraction to the determination of strychnine in blood [J].
Barroso, A ;
Gallardo, E ;
Margalho, C ;
Avila, S ;
Marques, EP ;
Vieira, DN ;
López-Rivadulla, A .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 816 (1-2) :29-34
[9]
Bessonneau V, 2013, BIOANALYSIS, V5, P783, DOI [10.4155/BIO.13.35, 10.4155/bio.13.35]
[10]
Low invasive in vivo tissue sampling for monitoring biomarkers and drugs during surgery [J].
Bojko, Barbara ;
Gorynski, Krzysztof ;
Gomez-Rios, German A. ;
Knaak, Jan M. ;
Machuca, Tiago ;
Cudjoe, Erasmus ;
Spetzler, Vinzent N. ;
Hsin, Michael ;
Cypel, Marcelo ;
Selzner, Markus ;
Liu, Mingyao ;
Keshjavee, Shaf ;
Pawliszyn, Janusz .
LABORATORY INVESTIGATION, 2014, 94 (05) :586-594