Determination of celecoxib in human plasma by normal-phase high-performance liquid chromatography with column switching and ultraviolet absorbance detection

被引:62
作者
Rose, MJ [1 ]
Woolf, EJ [1 ]
Matuszewski, BK [1 ]
机构
[1] Merck Res Labs, Dept Drug Metab, W Point, PA 19486 USA
来源
JOURNAL OF CHROMATOGRAPHY B | 2000年 / 738卷 / 02期
关键词
celecoxib;
D O I
10.1016/S0378-4347(99)00552-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method is described for the determination of celecoxib in human plasma. Samples were extracted using 3M Empore membrane extraction cartridges and separated under normal-phase HPLC conditions using a Nucleosil-NO2 (150x4.6 mm, 5 mu m) column. Detection was accomplished using UV absorbance at 260 nm. The HPLC method included a column switching procedure, in which late eluting compounds were diverted to waste, to reduce run-time to 12 min. The assay was linear in the concentration range of 25-2000 ng/ml when 1-ml aliquots of plasma were extracted. Recoveries of celecoxib were greater than 91% over the calibration curve range. Intraday precision and accuracy for this assay were 5.7% C.V. or better and within 2.3% of nominal, respectively. The assay was used to analyze samples collected during human clinical studies. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:377 / 385
页数:9
相关论文
共 18 条
[1]   INVITRO BIOTRANSFORMATION OF GLUCOCORTICOIDS IN LIVER AND SKIN HOMOGENATE FRACTION FROM MAN, RAT AND HAIRLESS MOUSE [J].
ANDERSSON, P ;
EDSBACKER, S ;
RYRFELDT, A ;
VONBAHR, C .
JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 1982, 16 (06) :787-795
[2]   BEHAVIOR OF BIARYLS, CONDENSED AROMATICS AND AZA-AROMATICS IN HIGH-PRESSURE LIQUID-CHROMATOGRAPHY USING SILICA MODIFIED WITH NITROPHENYL GROUPS (GROUP SEPARATION OF CONDENSED AROMATICS AND AZA-AROMATICS) [J].
BLUMER, GP ;
ZANDER, M .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1977, 288 (04) :277-280
[3]   =SI-N= BONDED STATIONARY PHASES FOR LIQUID CHROMATOGRAPHY [J].
BRUST, OE ;
SEBESTIA.I ;
HALASZ, I .
JOURNAL OF CHROMATOGRAPHY, 1973, 83 (AUG29) :15-24
[4]  
BUCKINGHAM J, 1982, DICT ORGANIC COMPOUN, P4836
[5]   SEPARATION OF POLYAROMATIC HYDROCARBONS BY LIQUID-SOLID CHROMATOGRAPHY USING 2,4,7-TRINITROFLUORENONE IMPREGNATED CORASIL I COLUMNS [J].
KARGER, BL ;
MARTIN, M ;
LOHEAC, J ;
GUIOCHON, G .
ANALYTICAL CHEMISTRY, 1973, 45 (03) :496-500
[6]  
Lane NE, 1997, J RHEUMATOL, V24, P20
[7]  
LANTTO O, 1982, CLIN CHEM, V28, P1129
[8]  
Majors RE, 1997, LC GC-MAG SEP SCI, V15, P220
[9]  
Mandell BF, 1999, CLEV CLIN J MED, V66, P285
[10]   ANALYTICAL CHIRAL SEPARATION OF THE STEREOISOMERS OF A NOVEL CARBONIC-ANHYDRASE INHIBITOR AND ITS DEETHYLATED METABOLITE, AND THE ASSIGNMENT OF ABSOLUTE-CONFIGURATION OF THE HUMAN METABOLITE AND CHIRAL DEGRADATION PRODUCTS [J].
MATUSZEWSKI, BK ;
CONSTANZER, ML ;
KIGANDA, M .
PHARMACEUTICAL RESEARCH, 1994, 11 (03) :449-454