The design, physical properties and clinical utility of an iris collimator for robotic radiosurgery

被引:102
作者
Echner, G. G. [2 ]
Kilby, W. [1 ]
Lee, M. [1 ]
Earnst, E. [1 ]
Sayeh, S. [1 ]
Schlaefer, A. [3 ]
Rhein, B. [2 ]
Dooley, J. R. [1 ]
Lang, C. [2 ]
Blanck, O. [3 ]
Lessard, E. [1 ]
Maurer, C. R., Jr. [1 ]
Schlegel, W. [2 ]
机构
[1] Accuray Inc, Sunnyvale, CA 94089 USA
[2] DKFZ, Dept Med Phys, D-69120 Heidelberg, Germany
[3] Med Univ Lubeck, Inst Robot & Cognit Syst, D-23538 Lubeck, Germany
关键词
CYBERKNIFE; DOSIMETRY; FILM;
D O I
10.1088/0031-9155/54/18/001
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
Robotic radiosurgery using more than one circular collimator can improve treatment plan quality and reduce total monitor units (MU). The rationale for an iris collimator that allows the field size to be varied during treatment delivery is to enable the benefits of multiple-field-size treatments to be realized with no increase in treatment time due to collimator exchange or multiple traversals of the robotic manipulator by allowing each beam to be delivered with any desired field size during a single traversal. This paper describes the Iris(TM) variable aperture collimator (Accuray Incorporated, Sunnyvale, CA, USA), which incorporates 12 tungsten-copper alloy segments in two banks of six. The banks are rotated by 30 degrees with respect to each other, which limits the radiation leakage between the collimator segments and produces a 12-sided polygonal treatment beam. The beam is approximately circular, with a root-mean-square (rms) deviation in the 50% dose radius of <0.8% (corresponding to <0.25 mm at the 60 mm field size) and an rms variation in the 20-80% penumbra width of about 0.1 mm at the 5 mm field size increasing to about 0.5 mm at 60 mm. The maximum measured collimator leakage dose rate was 0.07%. A commissioning method is described by which the average dose profile can be obtained from four profile measurements at each depth based on the periodicity of the isodose line variations with azimuthal angle. The penumbra of averaged profiles increased with field size and was typically 0.2-0.6 mm larger than that of an equivalent fixed circular collimator. The aperture reproducibility is <= 0.1 mm at the lower bank, diverging to <= 0.2 mm at a nominal treatment distance of 800 mm from the beam focus. Output factors(OFs) and tissue-phantom-ratio data are identical to those used for fixed collimators, except the OFs for the two smallest field sizes (5 and 7.5 mm) are considerably lower for the Iris Collimator. If average collimator profiles are used, the assumption of circular symmetry results in dose calculation errors that are <1 mm or <1% for single beams across the full range of field sizes; errors for multiple non-coplanar beam treatment plans are expected to be smaller. Treatment plans were generated for 19 cases using the Iris Collimator (12 field sizes) and also using one and three fixed collimators. The results of the treatment planning study demonstrate that the use of multiple field sizes achieves multiple plan quality improvements, including reduction of total MU, increase of target volume coverage and improvements in conformality and homogeneity compared with using a single field size for a large proportion of the cases studied. The Iris Collimator offers the potential to greatly increase the clinical application of multiple field sizes for robotic radiosurgery.
引用
收藏
页码:5359 / 5380
页数:22
相关论文
共 19 条
[1]
Performance evaluation of a CyberKnife® G4 image-guided robotic stereotactic radiosurgery system [J].
Antypas, Christos ;
Pantelis, Evaggelos .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (17) :4697-4718
[2]
Weak energy dependence of EBT gafchromic film dose response in the 50 kVp-10 MVp X-ray range [J].
Butson, MJ ;
Cheung, T ;
Yu, PKN .
APPLIED RADIATION AND ISOTOPES, 2006, 64 (01) :60-62
[3]
Radiochromic film for medical radiation dosimetry [J].
Butson, MJ ;
Yu, PKN ;
Cheung, T ;
Metcalfe, P .
MATERIALS SCIENCE & ENGINEERING R-REPORTS, 2003, 41 (3-5) :61-120
[4]
ECHNER G, 2008, Patent No. 2008011900
[5]
ECHNER G, 2006, Patent No. 2006119796
[6]
FULLER D, 2009, P 2009 CYBERKNIFE US
[7]
Virtual HDRSM cyberknife treatment for localized prostatic carcinoma:: Dosimetry comparison with hdr brachytherapy and preliminary clinical observations [J].
Fuller, Donald B. ;
Naitoh, John ;
Lee, Charles ;
Hardy, Steven ;
Jin, Haoran .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (05) :1588-1597
[8]
Design and evaluation of a variable aperture collimator for conformal radiotherapy of small animals using a microCT scanner [J].
Graves, Edward E. ;
Zhou, Hu ;
Chatterjee, Raja ;
Keall, Paul J. ;
Gambhir, Sanjiv Sam ;
Contag, Christopher H. ;
Boyer, Arthur L. .
MEDICAL PHYSICS, 2007, 34 (11) :4359-4367
[9]
Accuracy of the Monte Carlo Dose Calculation Algorithm for Cyberknife Treatment of Small Lung Lesions [J].
Hol, M. ;
Marijnissen, J. P. A. ;
van der Baan, P. ;
Heijmen, B. J. M. .
MEDICAL PHYSICS, 2008, 35 (06) :2953-+
[10]
KILBY W, 2009, IMAGE GUIDED ADAPTIV